LORDWORLD
LORDWORLD Nema L14-30P to 14-50R Adapter Cord 1Foot
Connects a 30 amp locking generator plug to a 50 amp dryer outlet using 10 AWG STW cable in a 32 cm length
- Connects a 30A generator to a 50A dryer outlet via L14-30P to 14-50R adapter
- Handles 125/250V dual-voltage loads with 30A plug and 50A receptacle ratings
- Built with STW 10AWG four-conductor cable for heavy-duty power delivery
- Compact 1-foot length (32CM) keeps generator-to-dryer runs short and tidy
- Yellow cord with black plugs ensures clear visibility and secure connections
What this adapter connects
This cord converts a Nema L14-30P 30-amp generator plug to a Nema 14-50R 50-amp dryer receptacle. It lets you power a dryer-style inlet from a standard generator outlet. The assembly is rated for 125/250-volt service.
Critical rating and cable spec
The adapter carries a 30-amp plug rating and a 50-amp receptacle rating at 125/250 volts. Its cord uses STW 10AWG four-conductor heavy-duty cable. The total length is 1-foot, approximately 32 centimetres.
Suitable and unsuitable uses
It suits owners who need a short, heavy-gauge link between a 30-amp generator and a 50-amp dryer inlet. It does not suit installations that require a longer reach or a higher continuous current than the 30-amp plug allows.
Highlights
- Connects a 30A generator to a 50A dryer outlet via L14-30P to 14-50R adapter
- Handles 125/250V dual-voltage loads with 30A plug and 50A receptacle ratings
- Built with STW 10AWG four-conductor cable for heavy-duty power delivery
- Compact 1-foot length (32CM) keeps generator-to-dryer runs short and tidy
- Yellow cord with black plugs ensures clear visibility and secure connections
Specifications
| Brand | LORDWORLD |
|---|
Questions about this item
What does the 30 A rating on the L14-30P plug mean when the adapter is connected to a 50 A dryer outlet?
The plug is rated for 30 A at 125/250 V, so the adapter can only carry up to 30 A regardless of the 50 A receptacle rating.
How does the NEMA 14-50R receptacle limit what I can plug into this adapter?
The 14-50R accepts standard four-prong dryer cords rated up to 50 A, but the 30 A plug and 10 AWG cord restrict the circuit to 30 A.
What clearance do I need for the 1-foot STW 10 AWG cord and moulded plugs?
The cord is about 32 cm long with moulded black plugs on each end, so allow space for the short stiff cable and both connector bodies.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.