LORDWORLD
LORDWORLD 6 ft 12 AWG NEMA 5-20P to 5-15/20R 20 A 125 V Power Extension Cord
Six-foot 12 AWG extension cord with NEMA 5-20P plug and combination 5-15/5-20R receptacle rated 20 A at 125 V
- UL / CUL listed for safe North American use
- 12 AWG heavy-duty conductors handle 20 A at 125 V
- NEMA 5-20P plug fits 20 A T-blade outlets
- Combination 5-15/5-20R receptacle accepts 15 A and 20 A plugs
- 83 m length gives flexible placement
NEMA 5-20P extension for 20 A circuits
This six-foot cord extends a NEMA 5-20P supply to a combination receptacle that accepts both 5-15 and 5-20 plugs. It is built for users who need to reach equipment rated for 20 A at 125 V in North American installations. The UL and CUL listings confirm compliance with the relevant safety standards for this connector family.
12 AWG conductors rated 20 A 125 V
The 12 AWG wiring provides the ampacity required for continuous 20 A loads at 125 V, giving headroom for high-draw devices such as workshop tools or commercial appliances. The combination receptacle passes the full 20 A rating through the 5-20 blade slot while also accepting 15 A plugs. The cord reaches its thermal limit at the rated 20 A, so loads above that value are not supported.
NEMA 5-20 interface constraints
The male 5-20P plug fits only 20 A receptacles with the characteristic T-shaped neutral slot, so it cannot be used on standard 15 A wall outlets. The female end accepts both 5-15 and 5-20 plugs, but the circuit breaker and wiring upstream must still be rated for 20 A to utilise the full capacity. The 1.83 m length is fixed and cannot be daisy-chained without violating the listing.
Highlights
- UL / CUL listed for safe North American use
- 12 AWG heavy-duty conductors handle 20 A at 125 V
- NEMA 5-20P plug fits 20 A T-blade outlets
- Combination 5-15/5-20R receptacle accepts 15 A and 20 A plugs
- 83 m length gives flexible placement
Specifications
| Brand | LORDWORLD |
|---|
Questions about this item
Will the NEMA 5-20P plug on this cord fit into my existing NEMA 5-15R wall outlet?
No, the NEMA 5-20P plug has a horizontal blade that requires a matching 20 A NEMA 5-20R receptacle; it will not insert into a standard 15 A NEMA 5-15R outlet.
How can I verify the cord is delivering the full 20 A 125 V rating after I connect it?
Check that the UL CUL markings are present on the jacket, ensure the 12 AWG conductors are fully seated in both the 5-20P plug and the 5-15/20R comb receptacle, and confirm your load does not exceed 20 A at 125 V.
Does the package include any adapters or mounting hardware, or is it just the 1.83 m extension cord?
The box contains only one 6 ft NEMA 5-20P to NEMA 5-15/20R extension cable; no extra adapters, brackets or fasteners are supplied.