Legend Valve
Legend Valve 508-280 crimp tool set with gauge and case
Crimp tool set for copper crimp rings includes go/no gauge and case meeting ASTM F1807/2098 standards
- TypePipes, Valves & Fittings
- Crimp copper rings accurately with ASTM F1807/2098 compliance
- Verify crimp quality instantly using included go/no gauge
- Organise and protect tools in supplied carry case
- Multi-size jaws cover 3/8 to 1 inch tubing
- California Proposition 65 warning for cancer and reproductive harm
PEX crimp tool set for ASTM F1807/2098
This Legend Valve 508-280 kit provides the tools needed to install copper crimp rings on PEX tubing. It includes a crimp tool, a go/no-go gauge for verifying connections, and a carrying case. The set suits plumbers and DIY installers working to ASTM F1807 and F2098 standards.
Manual operation with no external power
The crimp tool is hand-operated, so it produces no motor noise, draws no electricity, and generates no heat during normal use. The gauge is a passive metal component that also requires no power. Both pieces store in the supplied case when not in use.
Go/no-go gauge confirms crimp quality
The included gauge lets you check every connection against the ASTM F1807/2098 dimensional requirements. Installers who need a powered crimp tool or a different ring standard cannot use this set for those tasks.
Highlights
- Crimp copper rings accurately with ASTM F1807/2098 compliance
- Verify crimp quality instantly using included go/no gauge
- Organise and protect tools in supplied carry case
- Multi-size jaws cover 3/8 to 1 inch tubing
- California Proposition 65 warning for cancer and reproductive harm
Specifications
| Brand | LEGEND VALVE |
|---|---|
| Type | Pipes, Valves & Fittings |
Questions about this item
How do I install the crimp tool and which step is most often missed?
Place the copper crimp ring over the PEX tubing, insert the fitting, position the 508-280 tool jaws squarely on the ring, and squeeze fully; the step most often missed is verifying the crimp with the included go/no gauge before pressure testing.
What maintenance or replacement will the 508-280 set need over time?
The tool jaws and pivot should be kept clean and lightly lubricated; the go/no gauge must be checked periodically for wear, and the crimp rings themselves are single-use and replaced on every new connection.
What limit appears first during sustained crimping with the 508-280?
Operator fatigue from repeated high-force squeezes typically shows up before the tool itself reaches a mechanical limit, especially when making many ASTM F1807/2098 connections in succession.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.