Legend Valve
Legend Valve 114-107NL 1/2 CPVC x 3/8 OD T581 No Lead Angle Stop Valve
A no-lead chrome brass angle stop valve connects 1/2 CPVC pipe to 3/8 OD supply lines for multi-turn flow control
- TypePipes, Valves & Fittings
- No-lead brass construction meets Proposition 65 compliance
- 1/2 inch CPVC inlet connects directly to CPVC piping
- 3/8 inch OD outlet fits standard supply lines
- Multi-turn angle stop allows precise flow control
- Chrome-plated finish resists corrosion for lasting appearance
Legend Valve 114-107NL Angle Stop Valve
This angle stop valve connects 1/2 inch CPVC piping to 3/8 inch OD tubing for plumbing installations. It is designed for residential or light commercial water supply control. The chrome-plated brass body provides corrosion resistance. It meets PR-19 low-lead requirements for potable water systems.
No Lead Construction and Compliance
The valve features a no-lead brass composition that satisfies California Proposition 65 standards. It contains a chemical known to the state to cause cancer and reproductive harm. The T581 designation indicates the specific model configuration. Multi-turn operation allows precise flow adjustment.
Multi-Turn Operation Under Pressure
The multi-turn stem requires several rotations to move from fully open to fully closed. This design reduces water hammer risk during sustained pressure changes. Chrome plating protects internal components from mineral buildup during extended service. The angle pattern maintains flow direction in tight supply line connections.
Highlights
- No-lead brass construction meets Proposition 65 compliance
- 1/2 inch CPVC inlet connects directly to CPVC piping
- 3/8 inch OD outlet fits standard supply lines
- Multi-turn angle stop allows precise flow control
- Chrome-plated finish resists corrosion for lasting appearance
Specifications
| Brand | LEGEND VALVE |
|---|---|
| Type | Pipes, Valves & Fittings |
Questions about this item
How do I install the 1/2 CPVC connection on the 114-107NL angle stop, and what step is often missed?
Apply CPVC solvent cement to both the pipe end and valve socket, then insert fully and hold briefly; the step often missed is allowing the joint to cure completely before pressurising the line.
What maintenance or replacement will the chrome brass angle stop need over time?
The multi-turn stem packing may eventually seep; repacking or replacing the stem packing restores the seal without removing the valve body.
What limit appears first on the T581 no-lead valve during sustained high-temperature use?
The CPVC socket rating governs the maximum continuous temperature; exceeding it risks joint softening before the brass body reaches its own limit.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Keson MP301 Measuring Wheel Orange Tubular Steel Frame Metal Spoked Wheel 999Ft
Bazarc Auto Lock Inspection Loop Amber/Blue measurement tool
- Amber/Blue



