Lamotte 1452 Turbidity Calibration Standard 100 NTU 60 mL measurement tool
Turbidity calibration standard at 100 NTU in a 60 mL bottle for instrument verification
- TypeEnvironmental & Mechanical
- 100 NTU standard ensures accurate turbidity meter calibration
- 60 mL volume provides sufficient solution for multiple tests
- Lamotte 1452 model delivers reliable environmental measurement reference
- Lab-grade chemical quality supports consistent test results
- New condition guarantees uncontaminated calibration solution
Turbidity Standard 100 NTU
This Lamotte 1452 calibration standard provides a 100 NTU reference solution in a 60 mL volume. It is intended for technicians who calibrate turbidity meters in environmental or mechanical testing applications. The chemical-grade formulation supports accurate instrument verification in laboratory and field settings.
Replaces expired calibration fluid
Use this standard when existing calibration solution has passed its usable date or when a fresh reference is required for meter verification. The jump is worth it whenever instrument readings drift or regulatory checks demand a current traceable standard for 100 NTU calibration points.
Simple pour-and-measure use
Installation consists of opening the bottle and introducing the solution to the meter according to the instrument procedure. Common issues include using contaminated glassware, failing to rinse the sample cell, or applying the standard at a temperature far from the meter calibration temperature.
Highlights
- 100 NTU standard ensures accurate turbidity meter calibration
- 60 mL volume provides sufficient solution for multiple tests
- Lamotte 1452 model delivers reliable environmental measurement reference
- Lab-grade chemical quality supports consistent test results
- New condition guarantees uncontaminated calibration solution
Specifications
| Brand | LAMOTTE |
|---|---|
| Type | Environmental & Mechanical |
Questions about this item
What bottle volume does the 1452 standard come in for the turbidity meter?
The calibration standard is supplied in a 60 mL bottle that matches the 100 NTU concentration.
How do I install the 100 NTU solution into the instrument without contaminating the cell?
Rinse the cuvette with a small amount of the 1452 standard, discard the rinse, then fill with fresh solution for measurement.
When should the 60 mL bottle of 100 NTU standard be replaced after opening?
Replace the solution once it exceeds the manufacturer’s recommended shelf life or if the liquid appears cloudy or has visible particles.