Lab Safety Supply Inc
Lab Safety Supply 12K972 Gf Syringe Filters 1.0 um PK100
Glass-fibre syringe filters with 1.0 µm pores, 25 mm diameter, 100 mL capacity, 90 bar max pressure, Luer-Lok inlet and Luer-slip outlet, pack of 100
- TypeAssortments & Kits
- 0 µm pore size captures fine particles
- Glass fibre media handles 100 mL per filter
- Polypropylene housing withstands 90 bar pressure
- Luer-lok inlet ensures secure syringe fit
- Pack of 100 filters supports high-volume use
Purpose & User
The Lab Safety Supply 12K972 syringe filters use a 1.0 um glass-fibre membrane in a 25 mm polypropylene housing to remove particles from up to 100 mL of liquid per filter. They are supplied in a pack of 100 for laboratories that process high volumes of samples.
Sustained-load behaviour
Each filter withstands 90 bar inlet pressure through a Luer-lok connection while the Luer-slip outlet delivers filtered liquid without a barb. The glass-fibre media maintains flow consistency across the full 100 mL capacity during extended filtration runs.
Replacement scope
This pack replaces smaller quantities of 1.0 um glass-fibre syringe filters for users who need bulk supply and Luer-lok inlet compatibility. It is not suited for applications requiring sterile individual packaging, smaller pore sizes or non-Luer fittings.
Highlights
- 0 µm pore size captures fine particles
- Glass fibre media handles 100 mL per filter
- Polypropylene housing withstands 90 bar pressure
- Luer-lok inlet ensures secure syringe fit
- Pack of 100 filters supports high-volume use
Specifications
| Brand | LAB SAFETY SUPPLY |
|---|---|
| Type | Assortments & Kits |
Questions about this item
How much back-pressure can the 1.0 µm glass-fibre membrane handle during a long filtration run?
The filter is rated for a maximum pressure of 90 bar, so it will withstand sustained use without rupturing.
Which syringe fittings do I need on hand to connect these filters?
You need a syringe with a Luer-lok inlet and a Luer-slip outlet to match the filter connections.
Will the 25 mm polypropylene housing fit the filter holders I already use for 25 mm discs?
Yes, the 25 mm diameter matches standard holders designed for 25 mm syringe filters.
More in Test & Measurement Tools
Similar items
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Ridgid 37103 Replacement Imager Head 17mm 36 Inch
- Digital Multimeters
Ergotron 98-009-026 HX Triple Monitor Bow Kit Polished Aluminum measurement tool
- Tools and Hardware
FLUKE networks 11294000 Need-L-Lock Crimping Pliers measurement tool
FLUKE networks JackRapid Replacement Blade Head for Panduit NK6X88M NK688M NKP5E88M
- Test Equipment