KISSLER AND CO., INC.
KISSLER AND CO., INC. 1/4-Turn Angle Stop 5/8 In x 1/2 In HAWA 88-9240 equipment
Quarter-turn angle stop valve with chrome-plated brass body, 5/8-inch compression inlet and 1/2-inch slip outlet rated to 125 psi
- MaterialHAWA
- Weight0.31
- Quarter-turn operation for fast shut-off
- Chrome-plated brass resists corrosion
- 125 psi rating handles supply pressure
- 40 °F to 180 °F range suits hot and cold lines
- IAPMO/UPC/SA listed for code compliance
Quarter-Turn Angle Stop
The Kissler & Co 1/4-Turn Angle Stop connects a 5/8 inch compression inlet to a 1/2 inch slip outlet. A chrome-plated brass body, handle and stem resist corrosion while the quarter-turn mechanism provides fast shut-off. It is rated for 125 psi and a temperature range of 40 to 180 degrees F. The valve carries IAPMO/UPC/SA listing.
Replaces Multi-Turn Valves
This quarter-turn design replaces older multi-turn supply stops that require several rotations to close. The upgrade is worth it when quicker isolation is needed during fixture changes or emergency leaks. The 5/8 inch compression inlet fits existing copper or CPVC supply lines without adapters. The slip outlet accepts standard 1/2 inch risers or connectors.
Suits Residential And Light-Commercial Fixtures
Plumbers and maintenance crews use this stop for toilets, lavatories and similar point-of-use connections where a compact angle body fits tight supply spaces. It is not intended for high-pressure hydronic loops or steam service beyond the 125 psi rating. Installers needing a straight-body configuration or different inlet type should select an alternative model.
Highlights
- Quarter-turn operation for fast shut-off
- Chrome-plated brass resists corrosion
- 125 psi rating handles supply pressure
- 40 °F to 180 °F range suits hot and cold lines
- IAPMO/UPC/SA listed for code compliance
Specifications
| Material | HAWA |
|---|---|
| Weight | 0.31 |
| Brand | Kissler & Co |
Questions about this item
What inlet and outlet sizes does the 5/8 In x 1/2 In angle stop use?
The stop has a 5/8 in compression inlet and a 1/2 in slip outlet for direct connection to supply tubing.
How do you install the compression inlet without leaks?
Slide the nut and ferrule onto the tube, push the tube fully into the stop, then tighten the nut one full turn past hand-tight.
When should the quarter-turn handle or stem be replaced?
Replace if the handle turns stiffly, drips at the stem packing, or fails to shut off at the rated 125 psi.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Taylor Made 12" x 18" Jolly Roger Novelty Flag 1818 marine electronic
- Accessories



