KingSener
KingSener RRC2024 6600mAh 14.40V Li-ion battery for AEONMED VG70 HAMILTON C2
Replacement Li-ion battery delivers 6600mAh at 14.40V for AEONMED VG70 and HAMILTON C2 ventilators
- Battery TypeLi-ion
- Battery Capacity6600mAh/95.0WH
- Battery Voltage14.40V
- 6600 mAh capacity powers ventilators through extended shifts
- 40 V output matches AEONMED VG70 and Hamilton C2 requirements
- 0 Wh energy rating supports reliable long-duration operation
- Li-ion chemistry delivers stable voltage without memory effect
- Replaces RRC2024, JW-Y4S3P-6.6 and REF369106 part numbers
Product Identity
This KingSener RRC2024 is a 14.40V lithium-ion replacement battery rated at 6600mAh and 95.0Wh. It is built for the AEONMED VG70 and HAMILTON C2 lung ventilators. The pack uses cells made in China and comes in a black housing.
Suitability
It suits biomedical technicians and clinical engineers who need a direct replacement for part numbers RRC2024, JW-Y4S3P-6.6, 4ICR19/66-3, REF369106 or JW-2024. Facilities using other ventilator models or requiring a different voltage or capacity should look elsewhere.
Deciding Specification
The critical specification is the 14.40V 6600mAh lithium-ion chemistry in the RRC2024 form factor. Match this voltage, capacity and part number to the original battery label before ordering.
Highlights
- 6600 mAh capacity powers ventilators through extended shifts
- 40 V output matches AEONMED VG70 and Hamilton C2 requirements
- 0 Wh energy rating supports reliable long-duration operation
- Li-ion chemistry delivers stable voltage without memory effect
- Replaces RRC2024, JW-Y4S3P-6.6 and REF369106 part numbers
Specifications
| Brand | kingsener |
|---|---|
| Battery Type | Li-ion |
| Battery Capacity | 6600mAh/95.0WH |
| Battery Voltage | 14.40V |
Questions about this item
How do I install the RRC2024 battery in my AEONMED VG70 ventilator, and what step is often missed?
Power off the ventilator, open the battery compartment, insert the 14.40 V pack until the latch clicks, then run the on-screen battery calibration before clinical use.
What maintenance will the KingSener 6600 mAh Li-ion pack need over its service life?
Expect capacity fade after several hundred charge cycles; replace the pack when runtime no longer covers the required backup duration for the VG70 or C2.
What limit appears first during a prolonged ventilation session on battery power?
The 95.0 Wh capacity sets the maximum run time; once depleted the ventilator will shut down unless AC power is restored.