Johnson Controls Inc
Johnson Controls Solenoid Air Valve V11HBA-100 220/240VAC 0-25 psi
A pneumatic 3-way solenoid valve for 220/240 VAC circuits operating at 0-25 psi
- TypeThermostats & HVAC
- Mount in any position for flexible installation
- 3-way valve controls pneumatic devices via electrical circuit
- 220/240 VAC coil voltage for standard mains supply
- 0-25 psi operating range suits low-pressure systems
- Series V11 solenoid air valve built for HVAC use
Application fit
The Johnson Controls V11HBA-100 solenoid air valve suits pneumatic circuits that must be switched by a 220/240 VAC signal. It is built for HVAC and thermostat systems operating between 0 and 25 psi. Installers who need a 3-way valve for direct electrical control will find it appropriate. It is not for low-voltage control circuits or pressure ranges above 25 psi.
Electrical and pneumatic behaviour
The coil accepts 220 or 240 VAC mains supply without an external transformer. In normal operation the valve shifts position when energised and returns when power is removed. Power draw is limited to the solenoid coil rating at the stated voltages. No thermal management or noise specifications are provided for the device itself.
Mounting and integration
The valve can be mounted in any orientation, simplifying pipe routing in tight panels. No brackets, fittings or wiring harnesses are included in the package. The 3-way port arrangement allows direct piping to the pneumatic actuator without extra manifolds. Software or configuration tools are not applicable to this electromechanical component.
Highlights
- Mount in any position for flexible installation
- 3-way valve controls pneumatic devices via electrical circuit
- 220/240 VAC coil voltage for standard mains supply
- 0-25 psi operating range suits low-pressure systems
- Series V11 solenoid air valve built for HVAC use
Specifications
| Brand | Johnson Controls |
|---|---|
| Type | Thermostats & HVAC |
Questions about this item
How do I install the V11HBA-100 solenoid valve and what is the step people get wrong?
Mount the valve in any position using the 1/8-inch NPT ports; the step often missed is confirming the 220/240 VAC coil rating matches the supply before wiring.
What maintenance or replacement will the V11HBA-100 need later?
Inspect the internal plunger and spring annually; replace the coil if it no longer pulls in at 220/240 VAC or if seat leakage exceeds the 0-25 psi range.
What limit shows up first on the V11HBA-100 under sustained use?
The 25 psi maximum operating pressure is the first limit reached; sustained cycling at that pressure accelerates coil heating and seat wear.