Inficon
Inficon 710-202-G1 Pilot Plus Vacuum Gauge 1/4 in Flare
Digital vacuum gauge measuring 1 to 760,000 microns with 1/4 in flare fitting and multi-unit display
- Measures vacuum from 1 to 760,000 microns for deep evacuation verification
- Digital display shows microns, millibars, pascal and torr on one screen
- Operates reliably in ambient temperatures from 0 to 122 °F
- Connects directly to 1/4 in refrigerant flare fittings without adapters
- Powered by a 9 V battery with filters and carrying case included
Pilot Plus Vacuum Gauge 1/4 in Flare
The Inficon Pilot Plus is a digital vacuum gauge built for HVAC technicians who need accurate evacuation readings on air-conditioning and refrigeration systems. It connects directly to a 1/4 in refrigerant flare fitting and displays pressure in microns, millibars, pascal or torr. A 9 V battery powers the unit, and the kit includes filters plus a carrying case for site work.
Suited for technicians measuring deep vacuum
This gauge serves engineers who must verify evacuation levels down to 1 micron across a range that tops out at 760,000 microns. It operates reliably in ambient temperatures from 0 to 122 °F. Contractors who require wireless data logging, an integrated pump or a larger connection size should consider other instruments.
Measuring range 1 to 760,000 microns
The span from 1 to 760,000 microns determines whether the Pilot Plus matches the evacuation depth your procedures demand. If your specification calls for a tighter low-end limit or a different maximum, another gauge will be necessary.
Highlights
- Measures vacuum from 1 to 760,000 microns for deep evacuation verification
- Digital display shows microns, millibars, pascal and torr on one screen
- Operates reliably in ambient temperatures from 0 to 122 °F
- Connects directly to 1/4 in refrigerant flare fittings without adapters
- Powered by a 9 V battery with filters and carrying case included
Specifications
| Brand | INFICON |
|---|
Questions about this item
How much power does the 9 V battery supply when the gauge runs all day?
The gauge operates on a single 9 V battery; no external power source is required for continuous use.
What flare fitting must already be on the system for the 1/4 in connection to seal?
A standard 1/4 in refrigerant flare fitting on the service port is needed for the gauge to connect directly.
Will the microns display work correctly on an older R-22 manifold set?
The gauge reads 1 to 760 000 microns regardless of refrigerant type, so it functions with legacy R-22 systems.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



