Hubbell Incorporated
Hubbell Incorporated SHC1055 NPT 0.75-0.88 in Aluminum video accessory
A liquid-tight aluminium cord connector accepting 0.75 to 0.88 inch cables with a 1 1/2 inch MNPT box connection
- TypeNPT
- Length2.300
- ColorWhite
- Weight0.45
- Aluminium body resists corrosion in damp locations
- Liquid-tight seal protects cables from moisture ingress
- Accommodates cord diameters from 0.75 to 0.88 inches
- Straight 1 1/2 inch MNPT thread for standard box mounting
- Lightweight 0.45 unit simplifies handling and installation
Hubbell SHC1055 Cord Connector
The Hubbell SHC1055 is a straight liquid-tight cord connector built for 1 1/2 inch MNPT box connections. It accepts a single cable with a diameter between 0.75 in and 0.88 in. The aluminium body provides a silver finish while the gland appears white. This accessory suits installers needing a reliable NPT termination point.
Aluminium build and sealed entry
The aluminium construction resists corrosion in damp environments. A liquid-tight seal keeps moisture and dust from entering the enclosure through the cord entry. No external strain relief is fitted so the connector relies on the gland compression alone. The 2.300 NPT thread engages securely with the box fitting.
Simple installation profile
The connector measures 1 11/16 in from box face to end allowing it to sit close to the enclosure wall. Weighing 0.45 units it adds minimal load to the fitting. The straight style keeps the cable run direct without bends. Insulation is not included so the installer must follow local code for grounded applications.
Highlights
- Aluminium body resists corrosion in damp locations
- Liquid-tight seal protects cables from moisture ingress
- Accommodates cord diameters from 0.75 to 0.88 inches
- Straight 1 1/2 inch MNPT thread for standard box mounting
- Lightweight 0.45 unit simplifies handling and installation
Specifications
| Brand | Hubbell Wiring Device-Kellems |
|---|---|
| Model | SHC1055 |
| Type | NPT |
| Length | 2.300 |
| Color | White |
| Weight | 0.45 |
Questions about this item
How do I install the SHC1055 cord connector onto a 1 1/2 in MNPT box, and what step is often missed?
Thread the aluminum body onto the 1 1/2 in MNPT box connection, insert one cord between .75 in and .88 in diameter through the gland, then tighten the compression nut until the gland seals evenly — the step often missed is confirming the gland compresses fully around the cord without over-tightening the aluminum threads.
What maintenance or replacement will the SHC1055 need over time?
Inspect the gland and compression nut periodically for corrosion or cracking; replace the entire connector if the aluminum body shows pitting, the threads strip, or the liquid-tight seal no longer holds — no separate strain-relief parts exist to service.
What limit appears first when the SHC1055 runs continuously in a wet location?
The .75 in to .88 in cord-diameter range is the first constraint — cords outside this range cannot seal, so sustained exposure to moisture will breach the liquid-tight rating if the installed cord drifts out of tolerance.