Hubbell Incorporated
Hubbell Incorporated RACO RC200 Conduit Outlet Body, Aluminum, Trade Size 2 in
Aluminium conduit outlet body with two threaded hubs for 2 in IMC or RMC, C-style shape and 67 cu in capacity
- TypeCable Management & Conduit
- Color MappingSilver
- Threaded hubs enable secure conduit connections
- Powder-coated aluminum resists corrosion in harsh environments
- C-style body provides 67 cu in wiring capacity
- NEC compliant for code-approved installations
- Compatible with IMC and RMC conduit types
Conduit Outlet Body
The Hubbell RACO RC200 is an aluminium conduit outlet body built for trade size 2 inch installations. It provides a threaded connection point for IMC and RMC conduit runs in commercial and industrial electrical systems. The C‑shaped body offers 67 cu in of internal capacity for wire splices and bends.
Upgrade from smaller bodies
This unit replaces 1 inch or 1 1/2 inch outlet bodies when conduit fill calculations demand more cubic inches. The jump is worth it when the conductor count or bend radius exceeds the capacity of smaller trade sizes. It is not for buyers who need a hazardous‑location rated fitting.
Sustained load behaviour
Powder‑coated aluminium resists corrosion during long‑term exposure in damp or outdoor environments. The flat back and threaded hubs maintain mechanical integrity under continuous vibration and thermal cycling. The 1.323 lb weight reflects solid construction that does not deform when conduit is torqued to specification.
Highlights
- Threaded hubs enable secure conduit connections
- Powder-coated aluminum resists corrosion in harsh environments
- C-style body provides 67 cu in wiring capacity
- NEC compliant for code-approved installations
- Compatible with IMC and RMC conduit types
Specifications
| Type | Cable Management & Conduit |
|---|---|
| Brand | RACO |
| Color Mapping | Silver |
Questions about this item
What trade size hubs does the RACO RC200 accept for threaded conduit entry?
The body has two threaded hubs sized for trade size 2 in conduit, compatible with IMC and RMC.
Which step is most often missed when installing this outlet body onto rigid metal conduit?
Installers frequently forget to apply thread sealant and fully tighten both hub connections to maintain the powder-coated finish and NEC compliance.
When should the flat back gasket be replaced on this conduit outlet body?
Replace the gasket whenever the cover is removed for wire pulls or if visual inspection shows compression loss, cracking, or corrosion on the sealing surface.