Hubbell Incorporated
Hubbell Incorporated RACO 955 Electrical Box 98.5 cu in 6 Gang Galvanized Steel
A welded 6-gang galvanised steel box with 98.5 cu in capacity, concentric knockouts for 1/2 in. and 3/4 in. wiring, and compatibility with low-voltage partitions 947 or 949
- TypeElectrical Boxes & Covers
- 5 cu in capacity fits many conductors
- Six gangs wired in one box cuts install time
- Welded galvanized steel resists corrosion and impact
- Concentric 1/2 & 3/4 in. knockouts suit varied wiring methods
- Compatible with low-voltage partitions 947 or 949
98.5 cu in 6-Gang Electrical Box
The RACO 955 is a welded galvanized steel box offering 98.5 cubic inches of capacity across six gangs. It eliminates the need to assemble multiple boxes on site, saving installation time for electricians running multiple circuits in commercial or residential projects.
Thermals, Noise and Power Draw
As a passive metal enclosure, the box generates no heat, produces no noise and draws no electrical power during normal operation. Its galvanized steel construction simply houses and protects wiring connections without active components.
Concentric Knockouts and Cover Compatibility
Twenty 1/2 and 3/4 inch concentric knockouts plus six 1/2 inch and four 3/4 inch knockouts allow flexible conduit entry for varied wiring methods. The box accepts both flat and 3/4 inch raised device covers, while low-voltage partitions 947 or 949 can be added to separate circuits inside the same enclosure.
Highlights
- 5 cu in capacity fits many conductors
- Six gangs wired in one box cuts install time
- Welded galvanized steel resists corrosion and impact
- Concentric 1/2 & 3/4 in. knockouts suit varied wiring methods
- Compatible with low-voltage partitions 947 or 949
Specifications
| Brand | RACO |
|---|---|
| Type | Electrical Boxes & Covers |
Questions about this item
How do I mount the RACO 955 box and what is the common mistake with the concentric knockouts?
Mount the welded 6-gang box directly to framing using the integral mounting holes; the frequent error is removing the wrong ring of a 1/2 in. and 3/4 in. concentric knockout, leaving an oversized hole that requires a reducer.
What parts will need replacement or maintenance on the 955 box over time?
The galvanized steel body is maintenance-free; only the flat or 3/4 in. raised device covers and low-voltage partitions 947 or 949 may need replacement if damaged during device changes.
What is the first limitation reached when the 955 box is filled to capacity under continuous load?
The 98.5 cu in. volume limit governs the maximum conductor count; exceeding it violates fill calculations before thermal or mechanical limits become a concern.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thomas & Betts TY523M Cable Tie 18lb 4in Natural Nylon Stainless Steel Locking Clip Pack 100
CALBRITE S60700FDCC Weatherproof Electrical Box 5.90" x 2.83" 25 cu in
- Electrical Boxes &…
HOFFMAN A12P10G Interior Panel Steel 10.75in H 8.88in W 14 Gauge
- Electrical Boxes &…