We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Hubbell Incorporated

Hubbell Incorporated GFTWRST20R GFCI Receptacle 20A 125VAC 5-20R Red

SKU CH-JGYB-AVFZ0

A 20 A, 125 V AC duplex GFCI receptacle with tamper-resistant and weather-resistant Zytel 101 housing in red, flush-mounted via screw terminals

  • TypeWiring Devices
  • Tamper-resistant design prevents accidental contact
  • Weather-resistant housing suits damp locations
  • 20 A rating supports heavy-duty circuits
  • Red Zytel 101 housing aids quick identification
  • 125 V AC rating matches standard North American supply

Tamper-Resistant GFCI Receptacle

This Hubbell GFCI receptacle delivers 20 A, 125 V AC ground-fault protection in a single-gang, duplex 5-20R configuration. The red Zytel 101 housing is tamper resistant and weather resistant for demanding indoor or covered outdoor locations. Screw-terminal wiring and a flush-mount design suit standard electrical boxes. It meets NEC requirements for personnel protection.

Replaces Standard Duplex Outlets

Swap a non-GFCI 5-20R duplex where code now requires ground-fault protection — bathrooms, kitchens, garages, basements or exterior receptacles. The upgrade is worth it when a circuit lacks GFCI coverage and a single device must protect downstream loads. Not suited for buyers who need a blank-face GFCI, a hospital-grade variant or a device rated above 20 A.

Sustained Load Behaviour

The thermoplastics housing resists UV and impact during continuous exposure, while internal contacts maintain clamping force through thermal cycling. Trip response remains consistent under prolonged fault conditions without nuisance tripping from transient leakage. Screw terminals resist loosening under vibration, keeping the protective circuit intact over long service periods.

Highlights

  • Tamper-resistant design prevents accidental contact
  • Weather-resistant housing suits damp locations
  • 20 A rating supports heavy-duty circuits
  • Red Zytel 101 housing aids quick identification
  • 125 V AC rating matches standard North American supply

Specifications

BrandHUBBELL
TypeWiring Devices

Questions about this item

Will the flush-mount 5-20R body fit in a standard single-gang box?

The receptacle is a single-gang, flush-mount duplex with a NEMA 5-20R configuration, so it fits a standard single-gang box.

Which screw terminals accept the line and load conductors, and what is the common wiring mistake?

Use the brass screws for hot, silver for neutral, and green for ground; the most common error is reversing the LINE and LOAD pairs, which defeats the 20 A GFCI protection.

How often should the tamper-resistant, weather-resistant GFCI be tested and when must it be replaced?

Press the TEST and RESET buttons monthly; replace the unit immediately if it fails to trip, will not reset, or shows any cracking in the red Zytel 101 housing.