HOFFMAN
HOFFMAN AVK812 Louver Plate Kit 15.31 in. H x 9.5 in. W
Louvered vent kit with 12 louvers, 15.31 in. height and 9.5 in. width for enclosure air conditioners
- TypeElectrical Replacement Parts
- Improved airflow with 12 louvered vents
- Secure fit in 14.06 in by 8 in cutout
- Durable powder-coated mild steel frame resists corrosion
- Includes mounting hardware for quick installation
- Compatible with enclosure air conditioner units
Louver Plate Kit 812
The NVENT HOFFMAN AVK812 is a louvered vent kit designed for electrical enclosures that require filtered airflow. It mounts to an enclosure air conditioner to allow heat exchange while keeping debris out of the cabinet. The kit includes all necessary mounting hardware for a complete installation. Its mild steel frame has a grey powder-coated finish for corrosion resistance.
Replaces damaged vent frames
This kit serves as a direct replacement for worn or dented louver plates on existing enclosure cooling systems. The upgrade is worth it when the original frame no longer seals against the cut-out or when the powder coating has failed and rust has started. Swapping the frame restores the air conditioner’s intended airflow path without replacing the entire cooling unit.
Twelve louver airflow capacity
The frame provides twelve fixed louvers that handle steady airflow for standard enclosure cooling loads. It fits a cut-out measuring 14.06 inches high by 8 inches wide with a depth allowance of 0.5 inches. The frame itself is 15.31 inches high, 9.5 inches wide and 0.31 inches deep. It is not suited for enclosures requiring higher-volume forced-air cooling beyond what the twelve louvers can pass.
Highlights
- Improved airflow with 12 louvered vents
- Secure fit in 14.06 in by 8 in cutout
- Durable powder-coated mild steel frame resists corrosion
- Includes mounting hardware for quick installation
- Compatible with enclosure air conditioner units
Specifications
| Brand | NVENT HOFFMAN |
|---|---|
| Type | Electrical Replacement Parts |
Questions about this item
What are the exact cut-out dimensions for mounting the AVK812 louver plate?
The kit requires a cut-out of 14.06 in height by 8 in width with a 0.5 in depth allowance.
Which fasteners are included and what is the common alignment mistake?
Mounting hardware is supplied; installers often forget to centre the frame on the 15.31 in by 9.5 in opening before tightening.
How many louver blades does the AVK812 have and when should they be cleaned?
The frame contains 12 powder-coated mild-steel louvers; inspect and clear dust whenever enclosure airflow drops noticeably.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Thomas & Betts TY523M Cable Tie 18lb 4in Natural Nylon Stainless Steel Locking Clip Pack 100
CALBRITE S60700FDCC Weatherproof Electrical Box 5.90" x 2.83" 25 cu in
- Electrical Boxes &…
HOFFMAN A12P10G Interior Panel Steel 10.75in H 8.88in W 14 Gauge
- Electrical Boxes &…