HNZXIB
HNZXIB Stainless Steel High Pressure Reactor Autoclave Vessel FCF series 500ml
A 500 ml stainless-steel pressure reactor rated for 22 MPa and 350 °C with 1.5 kW heating and 120 N·cm stirring torque
- TypePressure Reactor
- MaterialSteel
- Capacity500ml
- Voltage220V
- 500 ml capacity handles laboratory-scale batches
- 350 °C maximum temperature enables high-heat reactions
- 22 MPa pressure rating supports demanding processes
- Stainless steel construction resists corrosion and contamination
- 5 kW heating power with ±1 °C control accuracy
500 ml High-Pressure Autoclave
The HNZXIB FCF-series vessel is a stainless-steel pressure reactor built for laboratory synthesis, corrosion testing and small-scale production. It handles temperatures up to 350 °C and pressures up to 22 MPa with a 1.5 kW electric heater and integrated stirring motor.
22 MPa Design Pressure
The vessel is rated for a maximum working pressure of 22 MPa (220 bar), which determines whether it suits your reaction parameters. Exceeding this limit risks vessel failure, so the rating is the single specification that confirms suitability for a given process.
500 ml Capacity with 350 °C Limit
The 500 ml internal volume accommodates modest batch sizes for alkylation, hydrogenation or calorimetry work. Headroom ends at the stated 350 °C temperature ceiling and 22 MPa pressure ceiling; processes requiring higher temperatures or larger volumes need a different reactor.
Highlights
- 500 ml capacity handles laboratory-scale batches
- 350 °C maximum temperature enables high-heat reactions
- 22 MPa pressure rating supports demanding processes
- Stainless steel construction resists corrosion and contamination
- 5 kW heating power with ±1 °C control accuracy
Specifications
| Type | Pressure Reactor |
|---|---|
| Material | Steel |
| Capacity | 500ml |
| Voltage | 220V |
Questions about this item
How does the 350 °C maximum temperature translate to actual reaction control inside the vessel?
The controller holds temperature within ±1 °C using PID regulation, and the 1.5 kW electric heater brings the 500 ml chamber to the set point for reactions such as hydrogenation or corrosion testing.
What does the 22 MPa pressure rating mean for the sealing and fittings on this autoclave?
The vessel is rated for 22 MPa (220 bar) working pressure with a stainless-steel body and a stirring torque of 120 N·cm, so gaskets, valves and the magnetic drive are sized to contain that pressure safely.
What bench space and services are needed to install the 500 ml reactor?
The unit runs on 220 V mains power, includes a lifting handwheel for head removal, and requires a stable bench area for the heating mantle, stir motor and PID controller.
Also in this aisle