HNZXIB DLSB-10/10 10L -10°C 110V/60Hz Laboratory Supply
A 10 L refrigerated circulator cools liquid to -10 °C with ±0.2 °C precision and delivers 20 L/min flow for laboratory cooling
- TypeCooling Chiller
- Temperature Range-10°C~RT
- Capacity10L
- Voltage110V
- Cools to -10 °C with a 10 L reservoir
- Maintains ±0.2 °C precision for repeatable results
- 20 L/min flow at 4–6 m lift supports diverse setups
- Microcomputer controller with digital display simplifies operation
- Mechanical refrigeration delivers 1894–884 W cooling capacity
Low-temperature circulator for laboratory use
The HNZXIB DLSB-10/10 is a 10L refrigerated circulator that delivers coolant down to -10°C. A microcomputer controller with digital display manages temperature precision to ±0.2°C. The unit operates on a 110V/60Hz supply and uses a brand-name compressor for reliable performance. It is designed to connect with rotary evaporators, jacketed reactors and similar lab apparatus.
Suits labs needing -10°C cooling with 10L volume
This circulator fits applications that require a 10L bath at -10°C with 20L/min flow and 4-6m lift. Buyers who need lower temperatures such as -20°C or -40°C, or larger reservoirs of 20L to 100L, should look at other models in the range. The 110V/60Hz power requirement also means it is not suited for 220V/50Hz mains without a separate version.
Temperature precision ±0.2°C at -10°C
The specified precision of ±0.2°C at the -10°C set point is the key figure that determines whether this unit meets a protocol's stability demands. If a process requires tighter control or a different base temperature, the specification will not match the requirement.
Highlights
- Cools to -10 °C with a 10 L reservoir
- Maintains ±0.2 °C precision for repeatable results
- 20 L/min flow at 4–6 m lift supports diverse setups
- Microcomputer controller with digital display simplifies operation
- Mechanical refrigeration delivers 1894–884 W cooling capacity
Specifications
| Type | Cooling Chiller |
|---|---|
| Temperature Range | -10°C~RT |
| Capacity | 10L |
| Voltage | 110V |
Questions about this item
How do I connect the 10 L reservoir to my rotary evaporator or jacket reactor without creating an air-lock?
Use the 20 L/min circulation pump with its 4–6 m lift; prime the lines before powering the chiller so the pump never runs dry.
Which part will need replacement first if the chiller runs daily at -10 °C?
The compressor and refrigerant circuit are the primary wear items; the microcomputer controller and digital display are solid-state and typically outlast the refrigeration system.
What is the first performance limit reached during continuous operation at full load?
Cooling capacity drops from 1894 W at higher temperatures to 884 W at the lowest set-point, so the 884 W floor is the limiting factor for sustained heat removal.