- TypePressure Reactor
- Temperature RangeRT~240°C
- MaterialSteel
- Capacity500ml
- 500 ml capacity handles larger batch synthesis
- PTFE lining resists acid and alkali attack
- Non-magnetic 0Cr18Ni9Ti steel body ensures structural strength
- Operating ceiling 240 °C with 220 °C safety limit
- Heating and cooling rates below 5 °C/min protect vessel integrity
500 ml hydrothermal reactor for research labs
The HNZXIB KH-series vessel holds 500 ml of reaction mixture and is rated for a maximum temperature of 240 °C with a safety limit of 220 °C. A PTFE inner lining provides acid and alkali resistance while the non-magnetic 0Cr18Ni9Ti stainless steel shell adds structural strength. It is intended for university teaching, research units and small-scale synthesis in new materials, energy and environmental engineering.
Controlled heating and cooling for repeatable
Heating and cooling rates are limited to 5 °C per minute to prevent thermal shock and maintain sealed integrity under pressure. The safety pressure rating is 3 MPa and the filling degree must not exceed 80 % of the 500 ml capacity. Natural cooling to room temperature is required before the lid is opened, ensuring consistent digestion of heavy metals, pesticide residues, food, water, sludge, rare earth products and organic matter.
Non-magnetic steel body
The stainless steel autoclave body resists corrosion and eliminates magnetic interference during handling. Double protection from the steel shell and Teflon lining allows repeated exposure to aggressive acid or alkali environments. Wooden case packaging protects the vessel during the 7 to 14 working day transit, and the supplier provides a one year warranty on the assembly.
Highlights
- 500 ml capacity handles larger batch synthesis
- PTFE lining resists acid and alkali attack
- Non-magnetic 0Cr18Ni9Ti steel body ensures structural strength
- Operating ceiling 240 °C with 220 °C safety limit
- Heating and cooling rates below 5 °C/min protect vessel integrity
Specifications
| Type | Pressure Reactor |
|---|---|
| Temperature Range | RT~240°C |
| Material | Steel |
| Capacity | 500ml |
Questions about this item
How much heat does the 240°C reactor add to a lab running all day?
The vessel operates up to 240 °C with a maximum heating and cooling rate of 5 °C per minute, so sustained use adds significant heat; plan ventilation and allow natural cooling to room temperature before opening.
What fittings or accessories must I already own to seal and heat the 500ml vessel?
The autoclave uses a non-magnetic 0Cr18Ni9Ti stainless steel body with a PTFE inner liner; you will need a compatible heating mantle or oven, pressure-rated tubing, and a torque wrench for the flange bolts.
Will my existing KH-series liners and racks fit this 500ml model?
This unit is the KH-500 with a 500 ml capacity; liners and racks from smaller KH models are not interchangeable because the flange diameter and liner height differ.