HAYWARD POOL PRODUCTS INC
HAYWARD POOL PRODUCTS INC SV20050STE 120V AC CPVC Solenoid Valve Trap
A 120V AC CPVC solenoid valve with a 2.3 Cv rating for controlling fluid flow in plumbing systems
- TypeDrain Components
- MaterialHAWA
- 120 V AC operation suits standard pool circuits
- CPVC body resists chlorine and chemical exposure
- Normally closed design prevents flow until energised
- EPDM seals handle treated water without degradation
- 3 Cv rating delivers strong flow through 1/2 in pipe
120V AC CPVC Solenoid Valve
The Hayward SV20050STE is a normally closed, two-way inline solenoid valve built for 120V AC operation. Its CPVC body and EPDM seals suit chemical-resistant fluid control in plumbing and pool equipment systems. The valve connects via 1/2 inch nominal pipe size with a 3/8 inch orifice and a Cv of 2.3.
Installers needing 120V AC inline shut-off
This valve suits technicians who require a compact, normally closed solenoid for 120V AC circuits in CPVC piping. It is not for installers needing a junction-box enclosure, a larger flow coefficient, or a valve rated for fuel gas or fuel oil service. Buyers needing a different voltage or pipe diameter should select an alternative model.
Flow capacity with 2.3 Cv rating
The 2.3 Cv rating provides measurable flow through the 3/8 inch orifice for typical water or inert gas applications at 120V AC. Headroom exists for standard pool and spa circulation demands within the valve's pressure limits. The valve runs out where system pressure differentials exceed the unspecified maximum for air or inert gas, or where fuel compatibility is required.
Highlights
- 120 V AC operation suits standard pool circuits
- CPVC body resists chlorine and chemical exposure
- Normally closed design prevents flow until energised
- EPDM seals handle treated water without degradation
- 3 Cv rating delivers strong flow through 1/2 in pipe
Specifications
| Type | Drain Components |
|---|---|
| Material | HAWA |
| Brand | Hayward |
| Model | SV20050STE |
Questions about this item
What pipe size and voltage must my plumbing and electrical supply match for the SV20050STE valve?
The valve requires a 1/2 in nominal pipe connection and a 120V AC power source to operate correctly.
Will the CPVC body and EPDM seals handle the same pressures as my existing metal piping?
The CPVC body and EPDM seals are rated for a Cv of 2.3; air and inert gas maximum pressure differential is not rated, so verify your system pressure stays within CPVC limits.
How can I confirm the normally closed SV20050STE opens when energised?
Apply 120V AC to the coil; the valve should open and allow flow through the 3/8 in orifice, then close again when power is removed.