Hayward Flow Control
Hayward Flow Control TBH2050ASTV0000 ball valve 1/2" CPVC/FPM true union 250 psi
A CPVC true-union ball valve handles corrosive chemicals and water at 250 psi with a locking tee handle
- Full-port design ensures unrestricted flow
- CPVC body resists corrosive chemicals and water
- True-union construction allows easy inline maintenance
- Locking tee handle prevents accidental operation
- Rated for 250 psi maximum operating pressure
Purpose-built flow control
The Hayward Flow Control TBH2050ASTV0000 is a manual two-way ball valve built for corrosive chemicals and water. Its CPVC body and full-port CPVC ball handle aggressive media while maintaining a straight-through flow path. A locking tee handle prevents accidental operation in process environments.
Pressure and media limits
Rated for 250 psi maximum operating pressure, the valve suits many industrial piping systems. Steam, combustible gas and vacuum service are not rated, so the valve must not be used in those duties. The three-piece true-union design allows inline maintenance without cutting pipe.
Installation notes
True-union ends let technicians remove the centre section for cleaning or seal replacement while the pipe stays in place. CPVC solvent-cement joints need correct primer, cement and cure time to avoid leaks. The locking handle adds a safety step — verify the valve is in the desired position before securing the lock. Systems needing higher pressure ratings or different media certifications will require alternative valves.
Highlights
- Full-port design ensures unrestricted flow
- CPVC body resists corrosive chemicals and water
- True-union construction allows easy inline maintenance
- Locking tee handle prevents accidental operation
- Rated for 250 psi maximum operating pressure
Specifications
| Brand | HAYWARD FLOW CONTROL |
|---|
Questions about this item
Which valve size and material combination suits my 1/2" CPVC line?
This true-union ball valve is built for 1/2" nominal pipe in CPVC with FPM seals, rated 250 psi for corrosive chemicals and water.
What does the 250 psi rating mean when the valve is installed?
It is the maximum operating pressure the valve body and seals can handle continuously at room temperature in a properly supported system.
How does the true-union design affect installation and maintenance?
The three-piece true-union body lets you remove the centre section for cleaning or seal replacement without cutting the surrounding CPVC pipe.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



