Hayward Flow Control
Hayward Flow Control PBV2075TPE1 Back Pressure Valve 3/4" 250 psi CPVC
Regulates system pressure at 250 psi through a 3/4-inch CPVC body with TFE and EPDM seals
- Reliable pressure regulation up to 250 psi
- Durable CPVC construction resists chemical corrosion
- Secure sealing with TFE and EPDM materials
- Compact 3/4-inch design fits standard piping
- Trusted Hayward Flow Control engineering quality
Industrial Back Pressure Valve 3/4 Inch
The Hayward Flow Control PBV2075TPE1 is a back pressure valve built for industrial plumbing systems. It regulates downstream pressure in chemical processing and water treatment lines. The CPVC body with TFE and EPDM seals resists aggressive fluids. It suits engineers who need reliable pressure control in corrosive environments.
Replaces Worn Valves In Existing Lines
This unit replaces failed or leaking back pressure valves in 3/4 inch piping. The upgrade is worth it when seals degrade or pressure settings drift beyond tolerance. New CPVC construction restores chemical compatibility and sealing performance. It fits the same pipe size without rework.
Rated For 250 Psi Maximum Pressure
The valve operates up to 250 psi at the stated pipe size. Exceeding this limit risks body deformation or seal failure. CPVC temperature limits also constrain the maximum safe working pressure. System designers must verify both pressure and temperature stay within the material envelope.
Highlights
- Reliable pressure regulation up to 250 psi
- Durable CPVC construction resists chemical corrosion
- Secure sealing with TFE and EPDM materials
- Compact 3/4-inch design fits standard piping
- Trusted Hayward Flow Control engineering quality
Specifications
| Brand | HAYWARD FLOW CONTROL |
|---|
Questions about this item
What pipe size and material does the PBV2075TPE1 valve connect to?
The valve has a 3/4 inch connection and a CPVC body, so it fits 3/4 inch CPVC piping systems.
How is the 250 psi back-pressure valve installed, and what step is often missed?
Install it in-line with flow direction arrows aligned; the step often missed is confirming the TFE seats and EPDM seals are lubricated and seated before tightening the unions.
Which internal parts of the PBV2075TPE1 will need replacement over time?
The TFE seats and EPDM seals are the wear items; plan to replace them when reseating no longer holds the 250 psi set pressure.