Harris
Harris KH1022 Hydrogen Regulator CGA-350 0-125 psi
Two-stage hydrogen regulator with CGA-350 inlet, 0-125 psi delivery range and chrome-plated brass body
- Two-stage regulation delivers stable 0-125 psi outlet
- Chrome-plated brass body resists hydrogen embrittlement
- CGA-350 inlet fits standard hydrogen cylinders
- 2-inch dual gauges show supply and delivery pressure
- Integrated needle and relief valves control flow safely
Harris KH1022 Hydrogen Regulator
The Harris KH1022 is a two-stage specialty gas regulator built for hydrogen service on cylinders with a CGA-350 inlet. It delivers a controlled outlet range of 0 to 125 psi through a 1/4 inch hose barb outlet with an integrated needle valve. The unit includes a relief valve and meets CGA E-4 standards for gas handling equipment.
Two-stage pressure control
Two-stage regulation reduces the cylinder supply pressure to the working range in two steps, so outlet pressure remains steady as the cylinder empties. The 2 inch supply gauge reads up to 4,000 psi while the delivery gauge covers the 0 to 125 psi range. Maximum rated inlet pressure is 3,000 psi, matching standard high-pressure hydrogen cylinders.
Chrome-plated brass construction
The body is machined from chrome-plated brass with a 2.125 inch diameter and uses a neoprene diaphragm for hydrogen compatibility. CGA-350 inlet threads connect directly to hydrogen cylinders without adapters. The 1/4 inch hose barb outlet accepts standard tubing, and the fitted needle valve allows fine flow adjustment at the point of use.
Highlights
- Two-stage regulation delivers stable 0-125 psi outlet
- Chrome-plated brass body resists hydrogen embrittlement
- CGA-350 inlet fits standard hydrogen cylinders
- 2-inch dual gauges show supply and delivery pressure
- Integrated needle and relief valves control flow safely
Specifications
| Brand | HARRIS |
|---|
Questions about this item
How much heat or noise does the KH1022 produce during continuous hydrogen regulation?
The regulator body is chrome-plated brass and operates without a motor or fan, so it generates no measurable heat or audible noise during all-day use.
What existing fittings are required to connect this CGA-350 inlet to a hydrogen cylinder?
The inlet uses a standard CGA-350 connection rated for 3,000 psi max inlet pressure, matching the cylinder valve found on hydrogen specialty-gas cylinders.
Will the two-stage design maintain steady delivery pressure if my older single-stage manifold fluctuates?
Yes, the two-stage construction reduces delivery-pressure decay as cylinder pressure drops, keeping the 0 to 125 psi outlet stable even when upstream supply varies.