We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Gorton Heating Corporation

Gorton Heating Corporation No. 1 3/4" OD x 1/2" ID Straight Air Eliminator

SKU CH-CE01-77R2J

Straight air eliminator with 3/4 inch OD and 1/2 inch ID connections removes trapped air from steam heating systems

  • TypeDrain Components
  • Selling UnitEach
  • Straight design simplifies installation in steam piping systems
  • 3/4" OD x 1/2" ID fits standard steam main connections
  • Removes trapped air to maintain efficient steam distribution
  • Gorton No. 1 model engineered for reliable air venting
  • Quantity guidance provided for short and long mains

Steam Main Air Venting

The Gorton No. 1 straight air eliminator removes trapped air from steam heating mains. It features a 3/4 inch outside diameter inlet and a 1/2 inch inside diameter outlet. The valve installs at the end of steam mains to allow air to escape so steam can fill the system quickly and evenly.

Sizing And Placement Guide

One or two units handle a short main or a main serving the warm side of a building. Two or three units are used at the end of a long main or a main running to the cold side. For larger buildings the manufacturer suggests moving up to a No. 2 air eliminator instead of adding more No. 1 units.

Steam System Interface Limits

The valve operates only on steam systems and vents air through its 1/2 inch ID outlet. It does not remove water or condensate and is not a drain trap. The fixed 3/4 inch OD by 1/2 inch ID connection sizes cannot be changed, so piping must match these dimensions exactly.

Highlights

  • Straight design simplifies installation in steam piping systems
  • 3/4" OD x 1/2" ID fits standard steam main connections
  • Removes trapped air to maintain efficient steam distribution
  • Gorton No. 1 model engineered for reliable air venting
  • Quantity guidance provided for short and long mains

Specifications

TypeDrain Components
Selling UnitEach

Questions about this item

Will the 3/4" OD x 1/2" ID connections fit my existing steam main piping?

The straight air eliminator has a 3/4-inch outside diameter and 1/2-inch inside diameter, matching mains built to those dimensions; verify your pipe OD and ID before installation.

How do I confirm the No. 1 air eliminator is venting correctly after fitting it?

When the system heats, the valve should release air with a steady hiss and then close silently once steam reaches it; no hissing or continuous steam loss means it is operating as intended.

Does the package include any pipe sealant or fittings, or must I buy them separately?

The unit is sold as a single air eliminator only; thread sealant, pipe dope or Teflon tape and any required nipples or couplings must be purchased separately.