GE
GE U050 Unmetered Power Outlet 10-50R 50 A 120/240V AC NEMA 3R
A 50 A unmetered power outlet with a 10-50R receptacle rated for 120/240V AC in a NEMA 3R steel enclosure
- TypeWiring Devices
- ColorTransparent
- 50 A capacity supports high-draw appliances
- 120/240V AC rating fits standard residential wiring
- NEMA 3R steel enclosure resists rain and sleet
- 10-50R receptacle accepts common range and dryer plugs
- Unmetered design delivers direct power without monitoring hardware
Purpose and Rating
The GE U050 is an unmetered surface power outlet rated for 50 A at 120/240V AC with a NEMA 10-50R receptacle. It is built for high-current single-phase connections where metering is not required. The steel housing carries a NEMA 3R enclosure rating for outdoor or damp locations. This device suits installers needing a direct, unmetered feed for large loads.
Suitable Installations and Limits
This outlet fits applications such as RV hook-ups, welders, ranges or other 50 A 120/240V equipment that use the 10-50R configuration. It is not for circuits requiring over-current protection at the device, because no circuit breaker is integrated. Buyers who need a metered connection, a different NEMA pin layout, or a lower amperage rating should look at other wiring devices.
Build Integration
The steel enclosure mounts on a surface and provides NEMA 3R protection against rain and sleet, so it can sit outside or in a garage without a separate weatherproof box. Because the unit supplies only the receptacle, the installer must provide upstream over-current protection and suitable conductors for 50 A service. The transparent cover allows visual confirmation of the connection status while keeping the contacts shielded.
Highlights
- 50 A capacity supports high-draw appliances
- 120/240V AC rating fits standard residential wiring
- NEMA 3R steel enclosure resists rain and sleet
- 10-50R receptacle accepts common range and dryer plugs
- Unmetered design delivers direct power without monitoring hardware
Specifications
| Brand | GE |
|---|---|
| Type | Wiring Devices |
| Color | Transparent |
Questions about this item
What circuit breaker rating is required for the 50 A NEMA 10-50R receptacle?
A dedicated 50 A double-pole breaker is required to supply the 120/240V AC circuit this outlet is rated for.
Will the NEMA 3R steel enclosure accept the same conduit sizes as older NEMA 1 enclosures?
The NEMA 3R rating adds rain-tight construction; conduit knockout dimensions follow standard trade sizes for surface wiring devices.
How can I verify the 120/240V split-phase wiring is correct after installation?
Measure 120 V from each hot terminal to neutral and 240 V between the two hot terminals with a multimeter.