GE U010S010GRP Steel Unmetered Surface Power Outlet 20 A 120V AC
Steel unmetered surface power outlet rated 20 A at 120 V AC with GFCI protection and NEMA 3R enclosure
- TypeWiring Devices
- ColorTransparent
- GFCI protection reduces shock risk in damp areas
- 20 A rating supports high-draw equipment on a single circuit
- NEMA 3R steel enclosure withstands rain and sleet outdoors
- 120 V AC compatible with standard North American power
- Surface-mount design installs quickly on walls or panels
Unmetered 20 A Surface Outlet
This GE steel enclosure provides a single unmetered 5-20R receptacle rated for 20 A at 120 V AC. It is built for surface mounting where a GFCI-protected feed point is required. The NEMA 3R rating makes it suitable for damp or outdoor locations. Electricians and facility managers use it to add a weather-resistant power drop without metering.
GFCI Protection and Steel Housing
The integrated GFCI trips on ground faults to protect users and downstream equipment. A steel cabinet resists impact and corrosion in exposed installations. No circuit breaker is included, so over-current protection must be supplied upstream. Power draw depends entirely on the connected load.
Cabinet Dimensions and Mounting
The interior measures 7 in by 5 in, giving space for wiring and the receptacle assembly. The enclosure ships empty of breakers, so installers add only the devices the circuit requires. No additional accessories or software are bundled with the unit.
Highlights
- GFCI protection reduces shock risk in damp areas
- 20 A rating supports high-draw equipment on a single circuit
- NEMA 3R steel enclosure withstands rain and sleet outdoors
- 120 V AC compatible with standard North American power
- Surface-mount design installs quickly on walls or panels
Specifications
| Brand | GE |
|---|---|
| Type | Wiring Devices |
| Color | Transparent |
Questions about this item
How do I mount the steel enclosure and which knockouts should I remove for a surface install?
Mount the 7-1/8 in high steel enclosure directly to the wall using the pre-drilled mounting holes; remove only the knockouts that match your conduit size so the NEMA 3R rating stays intact.
Will the GFCI module or the 5-20R receptacle need periodic replacement?
Test the GFCI monthly using the built-in test button; replace the entire outlet if the GFCI fails to trip or reset, as the receptacle and protection are a single unit.
At what sustained current does the single 5-20R receptacle become the limiting factor?
The receptacle is rated for 20 A at 120V AC; continuous loads above that rating will trip the upstream breaker and exceed the device’s listed capacity.