GE
GE THQL1115AF2 Arc Fault Circuit Breaker 15A 1 Pole 120/240V
Single-pole arc fault interrupter rated 15 A at 120/240 V AC with 10 kA interrupting capacity, plug-in design for Power Mark Gold load centres
- Arc-fault protection detects dangerous arcs
- 15 A rating suits standard lighting and receptacle circuits
- Single-pole design fits 120/240 V panels
- Plug-in mounting enables quick installation in compatible load centers
- 10 kA interrupting rating handles high fault currents
15 A Arc Fault Breaker
The GE THQL1115AF2 is a single-pole arc fault circuit interrupter rated at 15 amps for 120/240 V AC systems. It mounts by plug-in connection in compatible load centres and uses a toggle actuator for manual control. The screw-clamp terminals accept standard branch-circuit conductors. This device serves residential circuits that require arc fault protection under applicable electrical codes.
Sustained Load Behaviour
The breaker carries its 15 A rating continuously when installed in an enclosure that meets the 100 A frame-size environment. Its 10 kA interrupting rating at 120/240 V AC defines the maximum prospective fault current it can safely clear. Thermal and magnetic elements respond to prolonged overloads and short circuits respectively without nuisance tripping under normal load profiles. The arc detection circuitry monitors the waveform continuously during operation.
Installation Checks
Verify that the panelboard is a Power Mark Gold load centre or an AQ lighting panel listed for THQL series breakers. Confirm the bus stab spacing and depth accept the 3.3 in length and 1 in width plug-in form factor. Ensure the circuit voltage does not exceed 240 V AC and that no DC voltage is present on the protected conductor. The device is not rated for DC applications.
Highlights
- Arc-fault protection detects dangerous arcs
- 15 A rating suits standard lighting and receptacle circuits
- Single-pole design fits 120/240 V panels
- Plug-in mounting enables quick installation in compatible load centers
- 10 kA interrupting rating handles high fault currents
Specifications
| Brand | GE |
|---|
Questions about this item
Does the 15 A arc fault breaker run hot or make noise when it carries load all day?
The THQL series plug-in breaker has no moving parts except the toggle, so it operates silently and its temperature rise stays within the 10 kA interrupting rating limits at 120/240 V AC.
What panelboard must I already own for this 1-pole 15 A unit to install?
It is listed for Power Mark Gold load centers and AQ lighting panels that accept the THQL 100 A frame size.
Will the 3.3 in long THQL1115AF2 fit beside older THQL breakers already in my load center?
Yes, the 1-inch wide plug-in form factor matches the standard THQL footprint, so it seats directly alongside existing THQL poles.