GE THQC1120WL Miniature Circuit Breaker 20A 1 Pole 120/240V AC
A 20 A single-pole miniature circuit breaker rated 120/240 V AC with a 10 kA interrupting rating, DIN-rail mountable and UL Listed
- 20 A single-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating handles high fault currents
- DIN-rail or surface mount fits GE panelboards
- Lug terminals accept 14 to 8 AWG copper wire
- Compact 3.3 × 1 × 2.4 in frame saves panel space
GE THQC1120WL 20A Breaker for Panelboards
This GE THQC series miniature circuit breaker provides 20 A single-pole protection at 120/240 V AC for compatible GE panelboards. It mounts on a surface or DIN rail and uses a toggle actuator for manual switching. The unit carries a 10 kA interrupting rating at the rated voltage and accepts wire from 14 AWG to 8 AWG. It is UL Listed for code-compliant installations.
Replacing a worn single-pole breaker in a GE load
Swap this breaker when an existing 1-pole device in a GE panelboard shows nuisance tripping, physical damage or has reached the end of its service life. The 10 kA AIR rating matches the original specification for standard residential and light commercial feeds. The jump is worth it when the panelboard schedule calls for a THQC frame and the circuit requires 20 A at 120/240 V AC.
Tool-free DIN rail clip and lug terminals
The breaker snaps onto a DIN rail or surface mount without special tools, then wires land in the integral lug terminals. Ensure the mounting rail is secure and the lug screws are torqued to the panelboard manufacturer’s value so connections do not loosen under thermal cycling. Verify the panelboard is a GE model that accepts THQC frames before ordering.
Highlights
- 20 A single-pole protection for 120/240 V AC circuits
- 10 kA interrupting rating handles high fault currents
- DIN-rail or surface mount fits GE panelboards
- Lug terminals accept 14 to 8 AWG copper wire
- Compact 3.3 × 1 × 2.4 in frame saves panel space
Specifications
| Brand | GE |
|---|
Questions about this item
What panelboard depth is required for the THQC series 20 A breaker?
The breaker depth is 2.4 in, so the panelboard must provide at least that much clearance behind the mounting rail.
Which step is often missed when mounting this breaker on a DIN rail?
After clipping the breaker onto the rail, the lug screws must be torqued to the specified value before energising the circuit.
What wire gauge range should be kept on hand for future re-terminations?
The lugs accept 14 AWG through 8 AWG copper conductors, so keep that range available for any later rewiring.