GE
GE CR101H Manual Motor Starter 1P 16A Toggle 120V 240V 230V 2.31in
Manual motor starter with 16 A thermal overload protection for single-phase 120 V or 240 V circuits
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Single-phase motor control up to 240 V AC with 16 A toggle operation
- Thermal overload protection without separate heater elements simplifies installation
- One-pole NEMA starter rated 1 hp at 120 V and 1 hp at 240 V
- Compact 2.31 in depth fits tight panel spaces
- Transparent cover allows visual contact status check
Manual Motor Starter 16 A Toggle
The GE CR101H is a single-pole manual motor starter rated for 16 A at up to 230 V AC/DC. It provides thermal overload protection for single-phase motors up to 1 hp at 120 V and 1 hp at 240 V. Industrial electricians and maintenance technicians use it for direct on-line motor control.
Open-Style Enclosure Toggle Operation
The unit has no enclosure, so it mounts inside an existing panel or cabinet where the toggle switch remains accessible. A single thermal element is required for overload function, and the 2.31 in overall depth fits standard enclosures. Wiring connects directly to the starter terminals.
Verify Panel Space and Thermal Element
Confirm the enclosure has enough depth for the 2.31 in body and clearance for the toggle actuator. Ensure a compatible thermal element is available for the motor’s full-load current. The starter is single-phase only and not suited for three-phase loads.
Highlights
- Single-phase motor control up to 240 V AC with 16 A toggle operation
- Thermal overload protection without separate heater elements simplifies installation
- One-pole NEMA starter rated 1 hp at 120 V and 1 hp at 240 V
- Compact 2.31 in depth fits tight panel spaces
- Transparent cover allows visual contact status check
Specifications
| Brand | ABB |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
What does the 230 V AC/DC maximum voltage rating limit in practice?
The 230 V AC/DC maximum rating means the starter can only be applied on circuits that do not exceed 230 volts, so it suits 120 V and 240 V single-phase supplies but not higher voltages.
What mounting space does the 2.31 in overall depth require?
The 2.31 in overall depth is the distance the unit projects behind the mounting surface, so the enclosure or panel must provide at least that much clear depth.
How is the single thermal overload relay fitted, and what step is often missed?
One thermal overload relay snaps into the starter body; the step often missed is setting the relay’s current dial to match the motor’s full-load amperes before commissioning.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.