G-Techt Global Corporation DG25-L 20A 120V White GFCI Duplex Receptacle
A 20 A, 120 V GFCI duplex receptacle with built-in surge protection that guards against ground-fault shocks
- Protects against shock with 20 A ground-fault interruption
- Built-in surge protection guards connected equipment
- 25 A feed-through rating supports downstream loads
- 120 V NEMA 5-20R fits standard 20 A circuits
- White finish matches common residential décor
GFCI duplex receptacle for 20 A circuits
This white GFCI duplex receptacle is rated 20 A at 120 V and provides ground-fault protection for residential and light-commercial wiring. It fits a standard NEMA 5-20R outlet box and includes a built-in surge protector to guard connected equipment against transient voltage spikes.
Thermal and electrical behaviour in daily use
The device operates passively with no moving parts so it produces no audible noise and adds negligible heat to the enclosure. Power draw is limited to the sensing circuitry required for ground-fault detection and surge suppression.
Replaces standard duplex outlets without
Install this receptacle where code requires GFCI protection or where an older outlet lacks shock protection and surge suppression. The upgrade is most valuable in kitchens bathrooms garages and outdoor locations where ground faults are a known hazard.
Highlights
- Protects against shock with 20 A ground-fault interruption
- Built-in surge protection guards connected equipment
- 25 A feed-through rating supports downstream loads
- 120 V NEMA 5-20R fits standard 20 A circuits
- White finish matches common residential décor
Specifications
No published specifications for this item yet.
Questions about this item
How is the DG25-L GFCI duplex receptacle wired, and what step do installers often miss?
Connect the line terminals to the incoming 120 V supply and the load terminals to downstream outlets; the step often missed is attaching the grounding wire to the green screw on the 3-wire grounding duplex.
What maintenance will the DG25-L require over time?
Press the test button monthly to verify the 20 A shock protector trips, then press reset; replace the unit if it fails to trip or reset, as the built-in surge protector degrades after repeated surges.
What limit appears first when the DG25-L runs continuously at high load?
The 20 A rating is the first limit; sustained current above 20 A will cause the GFCI to trip and interrupt the circuit.
More in Electrical & Industrial Wire
Similar items
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Unique-Bargains 30 AWG Tin-Plated Copper Wrapping Wire Red 650ft
- Wire Wrapping Wire
TRANS USA PRODUCTS, INC. 6 Outlet Wall Tap 16000 White
Unique-Bargains Wrapping Wire 30 AWG Yellow 820ft P/N DM-30-1000
- Wire Wrapping Wire
PREMIERE RACEWAY PRODUCTS Wire Hider FRA-33414 1-1/2" White Right Angle Self Adhesive
Unique-Bargains DM-30-1000 30 AWG 250 m 820 ft Blue
- Wire Wrapping Wire