Fluke 52-2 Dual Input Thermometer Series II
Dual-input digital thermometer with 60 Hz noise rejection and backlit display showing T1, T2, T1-T2, MIN, MAX, or AVG readings for J, K, T, or E-type thermocouples
- Dual inputs let you compare two temperatures at once
- Large backlit display shows T1, T2 and T1-T2 simultaneously
- 60 Hz noise rejection keeps readings stable in industrial environments
- Works with J, K, T and E-type thermocouples for wide application coverage
Dual-Input Thermometer for Industrial Use
The Fluke 52-2 Series II is a dual-input digital thermometer built for contact temperature measurement on motors, insulation, breakers, pipes, corroded connections, liquids and wires. It accepts industrial standard J, K, T or E-type thermocouple sensors. The large backlit dual display shows any combination of T1, T2, T1-T2 plus MIN, MAX or AVG readings. Integrated 60Hz noise rejection helps maintain accuracy in electrically noisy environments.
Fits Toolkits Requiring Two Simultaneous Channels
The unit requires compatible thermocouple probes for each input channel to operate. It frees the operator from carrying two separate single-input meters when differential or comparative readings are needed. Buyers who need data logging, wireless connectivity or support for thermocouple types beyond J, K, T and E should consider other instruments. The thermometer suits technicians who need simultaneous dual-channel measurement in a single handheld device.
Highlights
- Dual inputs let you compare two temperatures at once
- Large backlit display shows T1, T2 and T1-T2 simultaneously
- 60 Hz noise rejection keeps readings stable in industrial environments
- Works with J, K, T and E-type thermocouples for wide application coverage
Specifications
No published specifications for this item yet.
Questions about this item
What temperature differential can the Fluke 52-2 display between its two inputs?
The dual display shows T1-T2 differential readings directly, so you can see the exact temperature difference between the two connected thermocouples without manual calculation.
How does the 60 Hz noise rejection help during extended measurements?
It filters out mains-frequency interference from nearby equipment, keeping readings stable and accurate during all-day use in industrial environments.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.
Keson MP301 Measuring Wheel Orange Tubular Steel Frame Metal Spoked Wheel 999Ft
Bazarc Auto Lock Inspection Loop Amber/Blue measurement tool
- Amber/Blue