Festo CPE14-M1BH-5/3ES-1/8 196936 air solenoid valve
A 5/3 exhaust-center solenoid valve with 1/8 ports for pneumatic control circuits
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- 14 mm valve width fits compact manifolds
- 5/3 exhaust centre function holds position safely
- G 1/8 port enables direct tubing connection
- 196936 part code simplifies reorder tracking
- 3-year parts cover supports long service life
Pneumatic control for electricians
The Festo CPE14-M1BH-5/3ES-1/8 is a 5/3-way solenoid valve designed for compressed-air circuits in electrical maintenance and automation tasks. Its 1/8-inch port size suits compact panel installations where space is limited. Electricians and control-panel builders use it to direct actuator motion reliably.
Red housing aids identification
The red finish lets technicians spot the valve quickly inside crowded cabinets or during fault-finding. Supplied as a single unit in a box, it arrives ready for mounting without extra fittings. No software or configuration tools are included or required for operation.
Air supply quality sets the limit
Performance depends on clean, dry compressed air within the valve's rated pressure range; contamination or pressure spikes will reduce service life. The 5/3 exhausted-centre function vents both outlets when de-energised, so the system must tolerate that state. No electrical interface beyond the solenoid coil is specified.
Highlights
- 14 mm valve width fits compact manifolds
- 5/3 exhaust centre function holds position safely
- G 1/8 port enables direct tubing connection
- 196936 part code simplifies reorder tracking
- 3-year parts cover supports long service life
Specifications
| Brand | FESTO |
|---|---|
| Model | CPE14-M1BH-5/3ES-1/8 |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
How long before the internal seals on the CPE14-M1BH-5/3ES-1/8 need replacing?
The manufacturer specifies a three-year parts coverage period for the valve, indicating the expected service interval for internal sealing components.
What limits continuous operation of the 196936 valve first — coil temperature or supply pressure?
The coil temperature rise during extended energising is the primary limit; the valve is rated for continuous duty within its specified pressure range.