FASCO
FASCO A270 Blower 3350/2800 RPM 1 Phase 208-230V 3350 RPM
Direct-drive rectangular blower with two-speed PSC motor for furnace replacement, 3350/2800 RPM at 208-230 V single phase
- ColorTransparent
- Delivers two-speed airflow for furnace versatility
- Operates on standard 208-230V single-phase power
- Permanent split capacitor motor ensures reliable starts
- Withstands inlet air temperatures up to 400°F
- Direct OEM replacement for Trane model 7062-5033
Direct-Drive Blower for Furnace Replacement
The FASCO A270 is a single-phase blower rated for 208-230 V AC at 50/60 Hz. It draws 0.5 A and uses a permanent split capacitor motor with Class B insulation. The unit runs at two speeds, reaching a maximum of 3,350 RPM. Wire leads provide the electrical connection for direct wiring into compatible furnace assemblies.
Replaces Trane OEM Models 7062-5033 and X38040369010
This blower serves as a direct substitute for the listed Trane manufacturer part numbers. The upgrade is justified when the original motor fails or when static pressure demands exceed the old unit's 3 3/8 in wc rating. Operation is rated for inlet air temperatures up to 400 °F, matching the original specification for high-heat furnace environments.
Fits 3 3/4 in Inlet with Wire-Lead Connection
The rectangular housing accepts a 3 3/4 in inlet diameter and requires no separate outlet duct adapter. Wire leads simplify installation inside the furnace cabinet without special connectors. The direct-drive design eliminates belt maintenance, while the two-speed capability allows airflow tuning for heating and cooling modes.
Highlights
- Delivers two-speed airflow for furnace versatility
- Operates on standard 208-230V single-phase power
- Permanent split capacitor motor ensures reliable starts
- Withstands inlet air temperatures up to 400°F
- Direct OEM replacement for Trane model 7062-5033
Specifications
| Brand | FASCO |
|---|---|
| Color | Transparent |
Questions about this item
What are the inlet diameter and voltage requirements for this FASCO A270 blower?
The blower has a 3 3/4 inch inlet diameter and operates on 208-230V AC single-phase power at 50/60 Hz.
How do I wire the electrical connection and what is the motor type?
Connect the supplied wire leads to a 208-230V single-phase supply; the motor is a permanent split capacitor type with Class B insulation.
When should I replace the blower based on temperature limits or wear?
Replace the unit if inlet air temperatures exceed 400 degrees F or if the motor fails to reach the rated 3350 RPM maximum speed.