Fans
Fans D2D160-BE02-11 blower 380V 700W 1195m3/h 450Pa 2700rpm 160mm 64db
Centrifugal blower delivering 1195 m³/h at 450 Pa with a 160 mm impeller at 2700 rpm, 380 V 700 W, 64 dB
- High airflow with 1195 m³/h delivery
- Strong 450 Pa pressure overcomes duct resistance
- Maintenance-free double ball bearings cut service needs
- All-metal cold-rolled steel housing withstands harsh sites
- Wide -25 °C to +55 °C operating range
Industrial centrifugal blower for ABB drives
This 380V centrifugal blower delivers 1195m3/h airflow at 450Pa static pressure for cooling ABB frequency converters. It operates at 2700rpm with a 700W motor and 64db noise level. The 160mm diameter unit fits industrial inverter enclosures requiring forced-air heat dissipation.
380V three-phase power requirement
The blower runs on 380V 50Hz mains and draws 2.2A at full load. It is not compatible with single-phase 230V supplies or DC inverter outputs. Installers must provide a three-phase connection matched to the 700W rating.
Maintenance-free double ball bearing design
Sealed bearings eliminate lubrication intervals in cement, chemical, HVAC, metallurgy, power, water treatment, marine, mining, oil and gas, rubber, plastics and food processing plants. The all-metal cold-rolled steel housing withstands ambient temperatures from -25 to +55 Celsius. It does not suit applications needing variable-speed EC control or lower acoustic signatures.
Highlights
- High airflow with 1195 m³/h delivery
- Strong 450 Pa pressure overcomes duct resistance
- Maintenance-free double ball bearings cut service needs
- All-metal cold-rolled steel housing withstands harsh sites
- Wide -25 °C to +55 °C operating range
Specifications
No published specifications for this item yet.
Questions about this item
How does 1195 m³/h airflow perform inside an actual cabinet?
The 1195 m³/h rating moves that volume against 450 Pa static pressure, so it clears heat from dense component layouts or filter banks rather than just open air.
What does the 380 V three-phase supply limit in practice?
It requires a 380 V 50 Hz three-phase feed; the 2.2 A draw at 700 W means cable sizing and breaker selection follow industrial three-phase rules, not single-phase domestic limits.
Will the 160 mm blade diameter fit my existing mounting pattern?
The 160 mm impeller sits in an all-metal cold-rolled sheet housing with maintenance-free double ball bearings; verify your cut-out and bolt centres against the housing flange before ordering.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.