ETCR 9100S H/L Voltage Clamp Current Meter AC 0.00mA~600A F33mm electrician tool
Measures AC leakage current from 0.00 mA to 600 A on lines up to 10 kV with a 33 mm clamp, peak hold and 99-group data storage
- TypeTest Equipment
- Color/FinishRed
- Item Count1 pack
- Selling UnitBox
- Parts3 Years
- Labor1 Year
- Measures AC leakage and load current up to 600A
- 33mm jaw fits cables on systems below 10kV
- Peak-hold captures transient spikes during fault finding
- Stores 99 data groups for later review and reporting
- Special alloy jaws with magnetic shielding reduce external interference
AC leakage current clamp meter
The ETCR 9100S measures AC leakage current from 0.00 mA up to 600 A on lines rated below 10 kV. Its 33 mm jaw opens around conductors without breaking the circuit. Special alloy jaws and magnetic shielding reduce external interference for stable readings. The meter also stores up to 99 data groups and offers peak-hold and data-retention functions.
For electricians and HV/LV ratio testing
Technicians who need non-contact leakage and load current checks on high- and low-voltage systems will find the range and jaw size suitable. The instrument also acts as a high/low voltage ratio tester for primary and secondary current verification. Buyers who require DC current measurement or an included English manual should look elsewhere.
Jaw opening limits conductor size
The fixed 33 mm clamp aperture sets the maximum cable or busbar diameter that can be measured. Conductors larger than this opening cannot be accommodated, so confirm the physical dimensions before purchase.
Highlights
- Measures AC leakage and load current up to 600A
- 33mm jaw fits cables on systems below 10kV
- Peak-hold captures transient spikes during fault finding
- Stores 99 data groups for later review and reporting
- Special alloy jaws with magnetic shielding reduce external interference
Specifications
| Brand | ETCR |
|---|---|
| Model | 9100S |
| Type | Test Equipment |
| Color/Finish | Red |
| Item Count | 1 pack |
| Selling Unit | Box |
| Parts | 3 Years |
| Labor | 1 Year |
Questions about this item
What does the AC 0.00mA to 600A range mean for leakage-current work?
It lets you measure both tiny leakage currents down to 0.00 mA and load currents up to 600 A on systems up to 10 kV with one clamp.
Will the F33mm jaw fit around my cables?
The 33 mm jaw opening accepts single conductors or small bundles up to that diameter; check your cable insulation OD before buying.
How do I store a reading in the 99-group memory?
Press the data-store button after the display settles; each press saves the current value into the next free slot until all 99 are used.