Eaton XTCF032C10A IEC Magnetic Contactor 1NO 120V AC 4P Non-Reversing
IEC magnetic contactor with 1NO auxiliary contact, 120 V AC coil, four poles and 18 A inductive rating
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC-rated contactor for standard industrial control
- 120 V AC coil suits common panel voltage
- Four poles switch three-phase plus neutral
- 18 A inductive / 45 A resistive load capacity
- DIN-rail or panel mount with screw terminals
IEC Magnetic Contactor with 4 Poles
The Eaton XTCF032C10A is a four-pole IEC magnetic contactor rated for 18 A inductive and 45 A resistive loads. It operates on a 110/120V AC coil and provides one normally open auxiliary contact for control circuits. The non-reversing design suits straightforward motor starting and isolation tasks in industrial panels.
Screw Terminals and DIN Rail Mounting
Screw terminals allow secure wire connections without specialised tooling. The contactor fits standard DIN rail or can be panel mounted, offering flexibility inside enclosures. A transparent housing lets technicians verify contact status visually during commissioning or troubleshooting. Frame size C keeps the footprint compact at 3.35 in high by 2.28 in wide.
For Simple Motor Control Panels
This contactor suits builders who need a basic non-reversing starter with a single auxiliary contact for status feedback. It is not for applications requiring reversing operation, multiple auxiliary contacts, or an integrated enclosure rating. Buyers who need those features should look at a different configuration.
Highlights
- IEC-rated contactor for standard industrial control
- 120 V AC coil suits common panel voltage
- Four poles switch three-phase plus neutral
- 18 A inductive / 45 A resistive load capacity
- DIN-rail or panel mount with screw terminals
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Will the 1NO auxiliary contact on the XTCF032C10A contactor wear out and need replacement?
The auxiliary contact is rated for 10 A; under normal switching duty it should last the contactor's mechanical life, but heavy inductive loads may shorten its service interval.
What is the first limit reached when the contactor runs continuously at full inductive load?
The 18 A inductive full-load current rating is the primary thermal limit; sustained operation above this value will cause the coil or contacts to overheat first.
How much heat does the XTCF032C10A generate when mounted on a DIN rail and powered at 120 V AC all day?
With a 110/120 V AC coil and 4-pole main contacts carrying up to 45 A resistive, the unit dissipates modest heat; the open-frame design and 3.35 in height allow passive convection cooling.