Eaton
Eaton XTCE025C10B IEC Magnetic Contactor 25A 240V AC 3P Non-Reversing 1NO
IEC magnetic contactor rated 25 A inductive and 45 A resistive at 240 V AC with three poles, one normally-open auxiliary contact and screw terminals for DIN-rail or panel mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- 25 A inductive rating handles motor loads
- 45 A resistive rating supports heating circuits
- 220/240 V AC coil matches common supplies
- Three-pole design switches three phases together
- DIN-rail and panel mounting fits standard cabinets
IEC Magnetic Contactor 25A 240V AC
The Eaton XTCE025C10B is a three-pole IEC magnetic contactor rated for 25 amps inductive load and 45 amps resistive load at 220 to 240 volts AC. It includes one normally open auxiliary contact and mounts on DIN rail or panel. The non-reversing design suits motor starting and isolation duties in industrial control panels.
Coil voltage limits control circuit design
The contactor operates on a 220 to 240 volt AC coil, so the control circuit must supply this exact voltage range for reliable pull-in and drop-out. A coil driven outside this band may fail to close or overheat, and the 25 amp inductive rating applies only when the coil is energised within specification.
Frame size C fixes mounting footprint
Frame size C determines the overall height of 2 inches and width of 3.5 inches, which dictates the DIN rail space required and the screw terminal layout. If the enclosure or rail spacing cannot accommodate these dimensions, the contactor will not fit regardless of its electrical ratings.
Highlights
- 25 A inductive rating handles motor loads
- 45 A resistive rating supports heating circuits
- 220/240 V AC coil matches common supplies
- Three-pole design switches three phases together
- DIN-rail and panel mounting fits standard cabinets
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Should I choose the 25 A inductive or the 45 A resistive rating for my load?
Use the 25 A inductive rating for motor or transformer loads and the 45 A resistive rating for heating elements or purely resistive circuits.
What does the 220/240 V AC coil voltage mean once the contactor is installed in a panel?
The coil will operate directly on standard single-phase mains between 220 V and 240 V AC without an external transformer.
How does the IEC frame size C and screw-terminal interface limit the wire size I can connect?
Frame size C with screw terminals accepts solid or stranded conductors up to the maximum cross-section defined by the IEC standard for this frame.