Eaton
Eaton XTCE018C01T IEC Magnetic Contactor 1NC 24V AC 3P Non-Reversing Screw
IEC magnetic contactor with 1 NC auxiliary, 24 V AC coil, 3 poles, 18 A inductive / 40 A resistive rating, non-reversing, screw terminals, DIN-rail or panel mount
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Reliable motor control with 18 A inductive rating
- Safe low-voltage operation at 24 V AC coil
- Compact 3.9 in height fits tight panels
- Flexible DIN rail or panel mounting options
- High 40 A resistive capacity for heating loads
Eaton 3-Pole IEC Contactor
The Eaton XTCE018C01T is a three-pole IEC magnetic contactor rated for 18 amps inductive and 40 amps resistive load. It operates on a 24 V AC coil and includes one normally closed auxiliary contact. The unit is designed for DIN rail or panel mounting in industrial control panels.
24 V AC Coil And Non-Reversing Operation
This contactor requires a 24 V AC control supply and provides non-reversing motor control only. The three main poles switch up to 5 hp at 240 V AC three-phase. It carries no enclosure rating, so the panel builder must provide appropriate environmental protection.
Screw Terminals On DIN Rail Mount
Installation uses screw terminals for both power and control wiring. The compact frame measures 3.9 inches high by 1.85 inches wide, fitting standard DIN rail or direct panel mount. Installers must verify coil voltage matches the control circuit to avoid coil damage.
Highlights
- Reliable motor control with 18 A inductive rating
- Safe low-voltage operation at 24 V AC coil
- Compact 3.9 in height fits tight panels
- Flexible DIN rail or panel mounting options
- High 40 A resistive capacity for heating loads
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Should I choose the 18 A inductive or 40 A resistive rating for my load?
Use the 18 A inductive rating for motor or transformer loads; the 40 A resistive rating applies only to heating elements or similar non-inductive loads.
What does the 18 A full-load inductive current mean when the contactor is installed in a panel?
It is the maximum continuous inductive current the main poles can carry at 240 V AC, 3-phase, corresponding to about 5 hp motor duty.
How does the 24 V AC coil voltage limit the control circuit design?
The coil requires a 24 V AC supply; control wiring and pilot devices must be rated for that voltage and the coil's inrush and sealed VA.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.