Eaton
Eaton XTCE015B01A IEC Magnetic Contactor 1NC 120V AC 3P Non-Reversing
Three-pole IEC magnetic contactor rated 15 A inductive and 22 A resistive with 110/120 V AC coil, 1 NC auxiliary contact and DIN-rail or panel mounting
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- IEC magnetic contactor rated for 15 A inductive loads
- 120 V AC coil voltage suits standard control circuits
- Three-pole design switches three phases simultaneously
- DIN-rail and panel mounting fits common enclosures
- Screw terminals provide secure wiring connections
Eaton XTCE015B01A Magnetic Contactor
The Eaton XTCE015B01A is a three-pole IEC magnetic contactor designed for industrial control circuits. It operates on a 110/120V AC coil and provides non-reversing switching for motor loads up to 15 A inductive or 22 A resistive. The unit mounts on DIN rail or panel and uses screw terminals for secure wiring.
Single 1NC Auxiliary Contact
This model includes one normally-closed auxiliary contact that changes state when the main poles close. The contact adds a feedback signal for status indication, interlocking or safety circuits without requiring a separate relay. It simplifies panel wiring by integrating the auxiliary function into the contactor frame.
15 A Inductive and 22 A Resistive Capacity
The contactor comfortably handles typical motor starters and resistive heating loads within the stated current ratings. It runs out of headroom when inductive loads exceed 15 A or resistive loads exceed 22 A, so larger frame sizes are required for higher current applications. The compact 1.5 in height and 3.5 in width fit standard DIN rail spacing.
Highlights
- IEC magnetic contactor rated for 15 A inductive loads
- 120 V AC coil voltage suits standard control circuits
- Three-pole design switches three phases simultaneously
- DIN-rail and panel mounting fits common enclosures
- Screw terminals provide secure wiring connections
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
How often will the screw-terminal connections on this contactor need re-torquing?
The screw terminals should be checked and re-torqued during routine panel maintenance, typically once per year, to ensure reliable contact under the 15 A inductive or 22 A resistive load ratings.
What thermal limit appears first when the contactor runs continuously at 15 A inductive load?
The coil and contact assembly are rated for continuous duty at 15 A inductive; the first limit reached is the maximum operating temperature of the insulation class, which the design keeps within spec at the rated current.
How much heat does the contactor dissipate when mounted on a DIN rail and powered at 120 V AC all day?
With a 120 V AC coil and 15 A through three poles, the contactor generates modest heat that is dissipated through its 1.5 in by 3.5 in frame; no forced-air cooling is required in a ventilated enclosure.