Eaton FAZ-C2/1-SP Circuit Breaker 2A 1 Pole 277/480V AC 15kA
Single-pole IEC supplementary protector rated 2 A with thermal-magnetic trip, 277/480 V AC and 48 V DC, 15 kA interrupting, DIN-rail mount, UL 1077 listed
- 277/480 V AC rating suits industrial control panels
- 15 kA interrupting capacity clears faults safely
- C-curve thermal-magnetic trip protects inductive loads
- Single-pole DIN-rail mount saves panel space
- UL 1077 recognised for supplementary protection
Eaton FAZ-C2/1-SP 2A Single-Pole Breaker
This Eaton FAZ series supplementary protector is a 2 A, single-pole device rated for 277/480 V AC and 48 V DC. It mounts on a DIN rail and uses a toggle actuator with thermal-magnetic trip characteristics. The unit carries a maximum interrupting rating of 15 kA at 277 V AC and meets UL 1077 requirements.
Suits panels needing a 2 A C-curve supplementary
Installers adding a 2 A C-curve supplementary protector to a DIN-rail assembly will find this breaker matches the required voltage and interrupting ratings. It is not for applications that demand a branch-circuit breaker listed to a different UL standard. Buyers needing a different current rating, pole count or trip curve should select another model.
2 A rating with C-curve thermal-magnetic trip
The 2 A rating combined with a C-curve thermal-magnetic trip characteristic defines the overcurrent response for this supplementary protector. This specification determines whether the device will co-ordinate correctly with the downstream load and upstream protection in your circuit.
Highlights
- 277/480 V AC rating suits industrial control panels
- 15 kA interrupting capacity clears faults safely
- C-curve thermal-magnetic trip protects inductive loads
- Single-pole DIN-rail mount saves panel space
- UL 1077 recognised for supplementary protection
Specifications
| Brand | EATON |
|---|
Questions about this item
Will the thermal-magnetic trip mechanism need periodic recalibration?
The thermal-magnetic trip is factory-calibrated and sealed; no user recalibration is required during the service life of this 1-pole FAZ breaker.
What is the maximum short-circuit current the breaker can safely interrupt at its rated AC voltage?
The breaker carries a 15 kA interrupting rating at 277 V AC, which is the highest fault-current limit specified for this device.
How much heat does the 2 A toggle unit dissipate when mounted on a DIN rail and running continuously?
At its 2 A rating the breaker operates within the temperature rise limits defined by UL 1077 for supplementary protectors; no additional cooling is needed for continuous duty.