Eaton
Eaton EMAT09-10 Switched PDU 1U 1440W 12A 120V 5-20P 8x5-15R
Switched rack PDU delivers 1440 W at 120 V through eight NEMA 5-15R outlets with remote network control in a 1U horizontal form factor
- TypeConsumer Electronics
- Switched control enables remote outlet management via network
- 1440 W capacity supports dense 120 V rack loads
- 8 NEMA 5-15R outputs power multiple servers from one feed
- 1U horizontal design fits standard 19" racks
- NEMA 5-20P input connects to common 20 A branch circuits
Switched PDU for Rack Power Management
The Eaton EMAT09-10 is a switched power distribution unit designed for 1U rack installations. It provides network-controlled outlet switching for eight NEMA 5-15R receptacles from a single 120 V AC input. This unit suits administrators who need remote power cycling for servers and network gear.
12 A Input Limits Total Connected Load
The NEMA 5-20P input plug delivers a maximum of 12 A at 120 V, capping the usable power at 1440 W across all eight outlets. Each output receptacle is rated for 15 A, but the aggregate draw cannot exceed the 12 A input rating. Builders planning higher-density deployments must account for this shared limit.
Horizontal 1U Form Factor Fits Standard Racks
The unit mounts horizontally in a 19-inch rack using 1U of vertical space, measuring 1.6 inches tall and 8 inches deep. This profile leaves room for adjacent equipment while keeping power connections accessible. Buyers needing vertical mounting or deeper chassis clearance should verify compatibility with their rack layout.
Highlights
- Switched control enables remote outlet management via network
- 1440 W capacity supports dense 120 V rack loads
- 8 NEMA 5-15R outputs power multiple servers from one feed
- 1U horizontal design fits standard 19" racks
- NEMA 5-20P input connects to common 20 A branch circuits
Specifications
| Brand | EATON |
|---|---|
| Type | Consumer Electronics |
| Shipping weight | 5.44 kg |
| Package size | 590 × 380 × 150 mm |
Questions about this item
Should I pick the 12 A model or the 16 A model for my 120 V rack?
The unit supplied is the 12 A version with a NEMA 5-20P inlet; the 16 A L5-20P variant is a different part number.
What does the 1440 W rating actually deliver to my servers?
It provides up to 1440 W of 120 V AC across eight NEMA 5-15R outlets, switched per outlet via the built-in network port.
What does the RJ-45 network connection let me control?
It enables IP-based outlet switching, power monitoring and reboot scheduling for each of the eight 5-15R receptacles.