We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.
Eaton
A general-duty fusible safety switch rated 60 A at 240 VAC with a NEMA 3R galvanised-steel enclosure and double padlocking capability
The Eaton DG322NRB is a fusible general-duty safety switch rated 60 amps at 240 volts AC three-phase. It houses Class H fuses and a neutral in a NEMA 3R metallic enclosure made of galvanised steel. The unit carries a 15 horsepower rating at 240 volts and is UL listed to UL98 and NEMA KS-1 standards.
This switch replaces non-fusible disconnects or open knife switches where overcurrent protection and a weather-resistant enclosure are required. The step up is justified when a 60 amp fusible device with a neutral and an IP14-rated NEMA 3R housing is specified for outdoor or damp locations. It covers 30 to 100 amp double padlocking and additional door locking capability.
The enclosure measures 10.9 inches high, 8.7 inches wide and 7.4 inches deep with four wiring terminals for three poles plus neutral. Metallic construction provides grounding continuity while the NEMA 3R rating sheds rain and sleet. Installers must supply Class H fuses and size conductors for the 60 amp rating; the switch frees the panel from separate fuse blocks and exposed blades.
| Brand | Eaton |
|---|---|
| Type | Electrical Equipment |
The NEMA 3R metallic enclosure measures 10.9 in high, 8.7 in wide and 7.4 in deep, so allow that footprint plus clearance for the cover swing and conduit entries.
The fusible switch accepts four wires on its 3PST contacts; follow the lug markings on the device for the correct tightening torque rather than guessing.
Replace the Class H fuses after any over-current event or when the switch reaches 60 A continuous load limits, and inspect the neutral block during each preventive maintenance cycle.
Also in this aisle
Same shelf, same checkout — eight coins and a 30-minute rate lock.
What you pay in, and what you read prices in.
Sent from your wallet at checkout
Display only — the catalogue is priced in USD
No currency matches that.
New here?
Already have one?
There is no automatic reset: this shop sends no mail, so there is no one-time link to ask for. Leave the address on the account and it gets picked up by hand.
Request noted
Nothing is on its way to your inbox — this shop sends no mail at all. Someone picks these up by hand.
Remembered it?