Eaton
Eaton AN19BN0C5E020 NEMA Magnetic Motor Starter 480V AC 3 Phase 20A 1NO
A NEMA magnetic motor starter with electronic overload protection adjustable from 4 A to 20 A, trip-class 10A/10/20/30, three-pole 480 V AC operation and one normally-open auxiliary contact
- TypeIndustrial Electrical Controls & Automation
- ColorTransparent
- Reliable motor protection with electronic overload relay adjustable 4 to 20 A
- Flexible trip-class selection covers 10A 10 20 and 30 for varied applications
- Space-saving surface-mount design fits standard panels without extra hardware
- Single normally-open auxiliary contact provides instant status feedback to control systems
- Three-phase 480 V AC operation up to 600 V AC maximum rating
Purpose and audience
The Eaton AN19BN0C5E020 is a NEMA magnetic motor starter rated for 480 V AC three-phase operation. It suits industrial control panels that need non-reversing motor protection with electronic overload capability.
Integration in a panel
Surface-mount construction and a 600 V AC maximum rating allow direct installation in standard enclosures. Three power poles handle the motor supply while a single normally-open auxiliary contact provides status feedback to a PLC or indicator without extra relays.
Behaviour under sustained load
Electronic overload protection adjusts from 4 A to 20 A and supports Trip Class 10A 10 20 30 for matched thermal response. The Freedom series design maintains consistent trip performance during repeated duty cycles without nuisance tripping.
Highlights
- Reliable motor protection with electronic overload relay adjustable 4 to 20 A
- Flexible trip-class selection covers 10A 10 20 and 30 for varied applications
- Space-saving surface-mount design fits standard panels without extra hardware
- Single normally-open auxiliary contact provides instant status feedback to control systems
- Three-phase 480 V AC operation up to 600 V AC maximum rating
Specifications
| Brand | Eaton |
|---|---|
| Type | Industrial Electrical Controls & Automation |
| Color | Transparent |
Questions about this item
Will the electronic overload trip at 20 A under continuous load?
The overload relay can be set up to 20 A and uses electronic protection with selectable Trip Class 10A/10/20/30 for sustained operation
How much heat does the starter dissipate when running all day?
The Freedom series NEMA starter uses electronic overload with no heater elements, reducing steady-state heat compared to thermal-bimetal designs
What supply voltage and phase must the panel already provide?
The coil requires 480 V AC three-phase power and the starter is rated for 600 V AC maximum
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.



