Eaton
Eaton Aeroquip 2090-6-6S Hydraulic Tee Fitting 3/8 NPTF 500 psi
A 3/8 inch NPTF female tee fitting rated to 500 psi for hydraulic hose connections
- Three female NPTF ports simplify branch connections
- 500 psi rating supports medium-pressure hydraulic systems
- 3/8 inch NPTF threads match common pipe sizes
- Tee shape directs flow in three directions
- All-female design accepts male adapters without extra fittings
Hydraulic Tee Fitting for 3/8 NPTF Systems
This Eaton Aeroquip 2090-6-6S tee connects three hydraulic lines with 3/8 inch NPTF female threads. It suits maintenance crews and machine shops building or repairing hydraulic circuits rated to 500 psi. The rigid steel body provides a fixed junction point for fluid distribution.
Pressure Rating and Leak-Free Sealing
Rated for 500 psi working pressure, the fitting handles typical hydraulic system demands without deformation. Each port uses standard NPTF taper threads that seal on the flanks, so no separate O-ring is required. The all-female design simplifies assembly with male-ended hose adapters or pipe nipples.
Sustained Operation in Fixed Installations
Under continuous pressure the rigid tee maintains alignment and thread engagement without the creep seen on swivel joints. The crimp-free construction means the fitting stays put once torqued, making it reliable for permanent plumbing on industrial machinery and mobile equipment alike.
Highlights
- Three female NPTF ports simplify branch connections
- 500 psi rating supports medium-pressure hydraulic systems
- 3/8 inch NPTF threads match common pipe sizes
- Tee shape directs flow in three directions
- All-female design accepts male adapters without extra fittings
Specifications
| Brand | EATON AEROQUIP |
|---|
Questions about this item
How do I install the 2090 tee fitting without cross-threading the 3/8 NPTF ports?
Apply PTFE tape or liquid sealant to the male threads, start each connection by hand to feel engagement, then tighten with a wrench one to two turns past finger-tight; the most common mistake is forcing the first turn and damaging the tapered threads.
What maintenance will the three female NPTF ports need over time?
Inspect for weeping at each joint during routine system checks; reapply thread sealant and retighten if leaks appear, and replace the fitting if the tapered seats show galling or deformation from repeated assembly.
At what pressure does the 2090 tee reach its rated limit during continuous operation?
The fitting is rated for 500 psi working pressure; sustained operation at or above this value risks permanent distortion of the 3/8 NPTF seats and eventual leakage.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.