DUSLAN
DUSLAN 6-Pack ER34615 3.6V 19000mAh D Lithium Primary Batteries
Six 3.6 V D-size lithium-thionyl-chloride cells deliver 19000 mAh each with a 10-year shelf life and operation from -55 °C to +85 °C
- Battery Type34615
- 19000 mAh capacity powers devices for years
- Lithium thionyl chloride chemistry delivers highest energy density
- Operates from -55 °C to +85 °C extremes
- Less than 1 % annual self-discharge enables 10-year shelf life
- Non-flammable electrolyte suits safety-critical applications
Six-pack D-size lithium thionyl chloride cells
The DUSLAN ER34615 pack supplies six primary lithium thionyl chloride D cells rated at 3.6 volts and 19000 mAh each. They are built for low-drain equipment such as alarms, metering units, GPS beacons and memory-backup circuits that need multi-year service without battery changes.
Continuous current capped at 200 mA
The chemistry delivers high energy density but cannot sustain heavy loads; maximum continuous draw is 200 mA and pulse current must stay below 400 mA. Operating range spans -55 °C to +85 °C while recommended storage tops out at +30 °C, and self-discharge remains under 1 % per year at +20 °C for roughly 10 years of shelf life.
Simple drop-in replacement but verify polarity
Each cell measures 34.2 mm diameter by 61.5 mm height and weighs about 110 g, matching standard D dimensions for direct installation. The pack is non-rechargeable and unsuited for high-drain devices; using it in such applications can damage the cells and the equipment.
Highlights
- 19000 mAh capacity powers devices for years
- Lithium thionyl chloride chemistry delivers highest energy density
- Operates from -55 °C to +85 °C extremes
- Less than 1 % annual self-discharge enables 10-year shelf life
- Non-flammable electrolyte suits safety-critical applications
Specifications
| Battery Type | 34615 |
|---|
Questions about this item
Which 19000 mAh D-cell pack should I choose for a device that draws 200 mA continuously?
The six-cell ER34615 pack supplies 3.6 V with a 200 mA continuous limit, matching the stated maximum draw.
What does the 19 Ah rating mean when the battery powers a 1 mA load at 20 °C?
At that load and temperature the cell delivers its nominal 3.6 V for the full 19 Ah capacity.
How does the 3.66 V open-circuit voltage affect a 3.6 V nominal system?
The open-circuit voltage is 3.66 V at 20 °C; under a 1 mA load it settles to the 3.6 V nominal value used for system design.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.