Dayton
Dayton GGS 47827 Direct Drive Blower 1/2 HP 1 Phase
A single-phase direct-drive blower motor rated at 1/2 HP with permanent split capacitor design, 115/230 V operation, 1,100 RPM, and totally enclosed air-over construction
- 1/2 HP direct-drive power for reliable airflow
- Single-phase 115/230 V operation suits standard supply
- Auto thermal protection guards against overheating
- Class F insulation handles 40 °C ambient temperature
- Totally enclosed air-over enclosure resists dust and moisture
Dayton 47827 Direct Drive Blower Motor
The Dayton 47827 is a single-phase direct drive blower motor rated at one-half horsepower. It uses a permanent split capacitor design with automatic thermal protection and Class F insulation. The motor is built in a totally enclosed air-over enclosure and mounts via a yoke. It serves as a direct replacement for the Dayton 1VCG2D unit.
Thermals noise and power in normal use
The motor draws 4.3 amps at 115 volts or 2.3 amps at 230 volts while running at 1,100 RPM. Its maximum ambient temperature rating is 40 degrees Celsius and the enclosure is designed for airflow cooling. Auto thermal protection helps prevent overheating during continuous operation. The single-speed design provides steady power consumption under typical load.
Behaviour under sustained load
The permanent split capacitor motor maintains its 1,100 RPM nameplate speed during extended duty cycles. Automatic thermal protection activates if internal temperatures exceed safe limits, allowing the motor to cool before resuming. Class F insulation supports the 40 degree Celsius ambient limit over long periods. The totally enclosed air-over construction keeps internal components protected while relying on the driven airflow for cooling.
Highlights
- 1/2 HP direct-drive power for reliable airflow
- Single-phase 115/230 V operation suits standard supply
- Auto thermal protection guards against overheating
- Class F insulation handles 40 °C ambient temperature
- Totally enclosed air-over enclosure resists dust and moisture
Specifications
| Brand | DAYTON |
|---|
Questions about this item
How do I wire the 115/230 V motor correctly for my supply voltage?
Connect the leads for either 115 V at 4.3 A or 230 V at 2.3 A as shown on the nameplate; the motor is single-phase, 60 Hz, permanent-split-capacitor with auto thermal protection and Class F insulation.
What maintenance will the sealed bearings need over time?
The totally enclosed air-over enclosure protects the bearings from dust; no routine lubrication is required, but inspect annually for noise or vibration that would indicate bearing wear.
At what ambient temperature does the motor reach its thermal limit?
The maximum rated ambient temperature is 40 °C; sustained operation above this will trip the automatic thermal protection and shut the motor down.