Dayton
Dayton 6WY48 Brake Motor 2 hp 3480 RPM 230/460 V AC 56HC Frame
Three-phase washdown brake motor delivers 2 hp at 3480 RPM with 230/460 V AC input and 56HC frame
- TypeBrake Motors
- 2 hp output drives demanding washdown applications
- 3480 RPM nameplate speed for high-speed cycles
- Dual 230/460 V AC voltage fits common three-phase supplies
- 56HC frame matches standard mounting dimensions
- Totally enclosed fan-cooled enclosure resists moisture and contaminants
Application Scope
This Dayton brake motor suits washdown environments that need a 2 hp three-phase motor with a 56HC frame. It runs at 3480 RPM on 230/460 V AC and carries a 1.15 service factor. The enclosure is totally enclosed fan cooled with Class F insulation rated for 40 °C ambient.
Voltage Fit
The motor is usable at 208 V and at 230/460 V, but it is not usable at 200 V. Installations that can only supply 200 V must select a different motor. Continuous duty and CW/CCW rotation are supported.
Critical Spec
The 56HC frame and 2 hp output at 3480 RPM determine whether this unit matches the mounting and power requirements of the driven equipment. Verify the frame and speed before ordering.
Highlights
- 2 hp output drives demanding washdown applications
- 3480 RPM nameplate speed for high-speed cycles
- Dual 230/460 V AC voltage fits common three-phase supplies
- 56HC frame matches standard mounting dimensions
- Totally enclosed fan-cooled enclosure resists moisture and contaminants
Specifications
| Type | Brake Motors |
|---|
Questions about this item
How often will the brake on the 6WY48 motor need inspection or replacement?
The brake is integrated into the motor; with continuous duty at 40 °C max ambient and Class F insulation, plan on checking lining wear during scheduled plant maintenance intervals.
What thermal limit appears first when the 2 hp motor runs continuously at 3480 RPM?
The insulation system is rated Class F with a 40 °C maximum ambient; sustained overload beyond the 1.15 service factor will reach that temperature limit before other components.
How much heat and noise should I expect from the totally enclosed fan-cooled 56HC frame running all day?
The TEFC enclosure moves cooling air over the frame while the motor draws 4.8 A at 230 V or 2.4 A at 460 V; audible output is typical for a 2 hp industrial brake motor in a washdown enclosure.