We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 5ZVC3 Circuit Breaker NDB2-63 C2/3 2A 3P 480V 7.5kA

SKU CH-TW63-52MVS

Three-pole supplemental protector rated 2 A at 480 V AC with 7.5 kA interrupting capacity, DIN-rail mount and screw-clamp terminals

  • ColorTransparent
  • Protects 3-phase circuits with 7.5 kA interrupting capacity at 480 V AC
  • Thermal-magnetic trip responds to overloads and short circuits without nuisance trips
  • DIN-rail mounting fits standard control-panel assemblies
  • Screw-clamp terminals accept 14 to 4 AWG conductors for secure wiring
  • UL 1077 recognised supplemental protector meets North American safety requirements

Product identity

The Dayton 5ZVC3 is a three-pole supplementary protector rated at 2 A and 480 V AC with a 7.5 kA interrupting capacity. It is designed for DIN-rail mounting in control panels where supplemental overcurrent protection is required.

Thermals noise and power

The device uses a thermal-magnetic trip mechanism calibrated to a C-curve characteristic for balanced overload and short-circuit response. No active cooling or fan is present, so operation is silent and power draw is limited to the inherent contact resistance of the screw-clamp terminals.

Accessories and software

The package supplies only the circuit breaker unit itself; no auxiliary contacts, shunt trips, configuration software or mounting hardware are included. Installers must provide DIN rail, wiring sized between 14 AWG and 4 AWG, and any required busbars or labels separately.

Highlights

  • Protects 3-phase circuits with 7.5 kA interrupting capacity at 480 V AC
  • Thermal-magnetic trip responds to overloads and short circuits without nuisance trips
  • DIN-rail mounting fits standard control-panel assemblies
  • Screw-clamp terminals accept 14 to 4 AWG conductors for secure wiring
  • UL 1077 recognised supplemental protector meets North American safety requirements

Specifications

BrandDAYTON
ColorTransparent

Questions about this item

How do I mount this three-pole breaker on DIN rail and what is the common wiring mistake?

Clip the unit onto a standard DIN rail until the latch engages, then insert each conductor fully into the screw-clamp terminals and tighten; the frequent error is leaving wire strands outside the clamp.

What upkeep will the thermal-magnetic trip mechanism need over time?

Periodically operate the toggle to verify free movement, inspect screw-clamp terminals for loosening, and replace the breaker if it trips at or below the 2 A rating during normal load.

What is the first limitation reached during a sustained fault on a 480 V AC circuit?

The 7.5 kA interrupting rating at 480 V AC is the limiting factor; fault currents above that level require upstream protection with a higher AIR rating.