Dayton
Dayton 48ZK04 3-Phase Motor 1.5 HP 182/4TC Frame 230/460V
Three-phase general-purpose motor delivers 1.5 HP at 1170 RPM in a 182/4TC frame with 230/460V dual voltage and 87.5% nominal efficiency
- TypeMotors
- Delivers 1.5 HP for demanding industrial tasks
- Dual-voltage 230/460 V suits varied power supplies
- 5 % nominal efficiency cuts energy waste
- 15 service factor handles intermittent overloads
- Totally enclosed fan-cooled design resists harsh environments
Dayton 48ZK04 Three-Phase Motor
The Dayton 48ZK04 is a general-purpose three-phase motor rated at 1.5 HP with a nameplate speed of 1170 RPM. It suits industrial equipment that requires continuous-duty operation on a 60 Hz supply.
Frame 182/4TC C-Face Mounting
This unit uses a C-face mounting pattern on a 182/4TC steel frame, allowing direct coupling to compatible gearboxes or driven loads. The dual-voltage 230/460V AC input lets the installer select the plant supply without a transformer.
TEFC Enclosure Class F Insulation
The totally enclosed fan-cooled design and Class F insulation support a maximum ambient temperature of 40 °C. Nominal efficiency is 87.5 percent at a 1.15 service factor, with full-load currents of 4.44 A at 230 V or 2.22 A at 460 V.
Highlights
- Delivers 1.5 HP for demanding industrial tasks
- Dual-voltage 230/460 V suits varied power supplies
- 5 % nominal efficiency cuts energy waste
- 15 service factor handles intermittent overloads
- Totally enclosed fan-cooled design resists harsh environments
Specifications
| Brand | DAYTON |
|---|---|
| Type | Motors |
Questions about this item
What is the service factor that limits continuous overload on this 1.5 HP motor?
The motor has a 1.15 service factor, so it can handle 15 percent above nameplate horsepower for short periods before thermal limits are reached.
How much current does the motor draw at full load on 460 V, and what does that mean for heat?
At 460 V the full-load current is 2.22 A; with 87.5 percent nominal efficiency and Class F insulation the motor runs within a 40 °C maximum ambient temperature.
What supply voltage and phase must the site already provide for this motor to operate?
The motor requires a three-phase 230/460 V AC, 60 Hz supply and a C-face mounting arrangement on an 182/4TC frame.
Also in this aisle
People compared these
Same shelf, same checkout — eight coins and a 30-minute rate lock.