We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 33V904 10 A 3-pole D-curve DIN rail circuit breaker

SKU CH-AD32-H4VKG

DIN-rail mounted 10 A three-pole D-curve breaker rated 480 V AC with 10 kA interrupting capacity

  • 10 A D-curve protection for high inrush loads
  • Three-pole 480 V AC switching for three-phase circuits
  • 10 kA interrupting capacity at 480 V AC
  • DIN rail mount with lug terminals for 54–70 AWG wire
  • UL 489 listed and CE marked for US and Canada

10 A D-curve three-pole breaker

The Dayton 33V904 is a 10 A three-pole miniature circuit breaker with a D-curve thermal-magnetic trip. It is built for industrial control panels that need IEC-style protection on 480 V AC three-phase circuits.

DIN rail mount with lug terminals

The unit clips onto a standard DIN rail and uses lug terminals that accept conductors from 54 AWG up to 70 AWG. Its 32 A frame size fits within the NDB2T-63 series envelope, leaving adjacent rail space for additional modules or wiring duct.

Replaces lower-rated or C-curve devices

Panels currently using a 10 A C-curve breaker that trips on motor inrush can move to this D-curve model for higher magnetic withstand. The step up is justified when the load includes transformers, solenoids or other high-inrush equipment that the existing breaker cannot hold.

Highlights

  • 10 A D-curve protection for high inrush loads
  • Three-pole 480 V AC switching for three-phase circuits
  • 10 kA interrupting capacity at 480 V AC
  • DIN rail mount with lug terminals for 54–70 AWG wire
  • UL 489 listed and CE marked for US and Canada

Specifications

BrandDAYTON

Questions about this item

What is the maximum short-circuit current the 33V904 can interrupt at 480 V AC?

The breaker has a maximum AIR rating of 10 kA at 480 V AC, meaning it can safely clear fault currents up to that level.

How much heat will the 33V904 dissipate inside a closed panel during continuous 10 A operation?

The thermal-magnetic trip mechanism generates heat proportional to load current; at full 10 A rating the device meets UL 489 temperature-rise limits for its 32 A frame size.

Which wire gauges can be terminated on the 33V904 lugs without adapters?

The lug terminals accept solid or stranded conductors from 54 AWG up to 70 AWG per the manufacturer's specification.