We take cryptocurrency — so the coins you hold can buy real hardware.Pay in crypto, spend it on real hardware. Free insured shipping worldwide over $399. Plain, unbranded boxes, sent from Germany.Free insured shipping over $399. Your rate is locked for 30 minutes once checkout opens.Rate locked 30 minutes. Every item sealed, serial-checked and covered by a 24-month warranty.Sealed, 24-month warranty.

Saved items Sign in

Dayton

Dayton 31LH41 1/3 HP three-phase motor 230/460V 56C frame

SKU CH-S6Q7-M34N4

Three-phase general-purpose motor delivering 1/3 HP at 1160 RPM with 230/460V dual-voltage operation and 56C frame mounting

  • Three-phase design delivers balanced power at 230/460 V AC
  • 1/3 HP output with 1160 RPM suits continuous HVAC duty
  • 56C C-face mounting simplifies direct coupling to pumps or fans
  • Service factor 1.35 provides extra capacity for peak loads
  • Class F insulation and ball bearings support 40 °C ambient operation

Application fit

The Dayton 31LH41 is a three-phase general-purpose motor rated at 1/3 HP for 230/460V AC supplies. It suits OEMs and maintenance teams that need a direct-drive unit for pumps, fans or conveyors where a C-face mount and continuous-duty cycle are specified.

Build and mounting

The open drip-proof steel frame carries ball bearings and Class F insulation with a 1.35 service factor. A 56C C-face flange provides direct coupling to driven equipment, while dual-voltage windings allow connection to either 230 V or 460 V three-phase networks.

Interface limits

The motor delivers 1160 RPM nameplate speed at 60 Hz with a nominal efficiency of 71.4 percent. Full-load current is 1.5 A at 230 V or 0.76 A at 460 V, and the design has no internal thermal protection. Operation is rated for a maximum ambient temperature of 40 degrees C.

Highlights

  • Three-phase design delivers balanced power at 230/460 V AC
  • 1/3 HP output with 1160 RPM suits continuous HVAC duty
  • 56C C-face mounting simplifies direct coupling to pumps or fans
  • Service factor 1.35 provides extra capacity for peak loads
  • Class F insulation and ball bearings support 40 °C ambient operation

Specifications

BrandDAYTON

Questions about this item

What voltage does the 56C-frame motor run on, and what current does it draw at full load?

It operates on 230/460 V AC three-phase and draws 1.5 A at 230 V or 0.76 A at 460 V.

Which mounting pattern and shaft style does the 56C frame use?

The motor has a C-face mounting flange and a keyed shaft that matches the NEMA 56C standard.

How do I wire the dual-voltage motor for 230 V or 460 V supply?

Connect the nine leads in parallel for 230 V or in series for 460 V, following the diagram on the nameplate.